Communications Option Station Address Monitor
Program Communications Communication Options
This parameter is used in the setup of the communications net-
work by reading the Media Access Code (MAC) address of the
ASD that is connected to a node of the communications system.
The MAC Address is set via DIP switches of the optional device.
See the DeviceNet Option Instruction Manual (P/N 58683) for
additional information on this parameter.
Communications Option Speed Switch Monitor DeviceNet/
CC-Link
Program Communications Communication Options
This parameter is used in the setup of the communications net-
work by reading the hardware-specific settings of the option card
being used with the ASD.
If using the DEV002Z Devicenet card, this parameter reads the
hardware switch SW300 setting of the Devicenet card. SW300
sets the baud rate and the MAC address of the option card that is
connected to a node of the communications system.
See the DeviceNet Option Instruction Manual (P/N 58683) for
additional information on this parameter or see the instruction
manual for the option being used with the Q9 Plus ASD.
Free Notes
Program Communications Communication Settings
This is an unused parameter that has allocated memory space.
The space may be used at the discretion of the user. This space
may be used to store information or a note to be transferred using
communications.
Network Option Reset Setting
Program Communications Communication Settings
This parameter plays a role in the setup of the communications
network by establishing the targets of a Reset command received
via the communications link.
Settings:
0 — ---
1 — Reset Option Board and ASD
https://www.toshiba.com/tic/
F853
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
F900
Direct Access Number —
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Minimum — 0
Maximum — 127
Direct Access Number —
Parameter Type — Hardware
Selectable
Factory Default — 0
Changeable During Run — Yes
Minimum — 0
Maximum — 255
Direct Access Number —
Parameter Type — Numerical
Factory Default — 0
Changeable During Run — Yes
Minimum — 0
Maximum — 65535
Direct Access Number —
Parameter Type — Selection List
Factory Default — - - -
Changeable During Run — No
F853
F854
F880
F899
227