Positioning Via A Cc-Link Network; Additional Connections - Mitsubishi Electric MR-J3-T Quick Start Manual

Servo amplifier with point table positioning
Hide thumbs Also See for MR-J3-T:
Table of Contents

Advertisement

Positioning via a CC-Link Network

5
Positioning via a CC-Link Network
As an alternative to using digital signals you can also control positioning with MR-J3-T servo
amplifiers via a CC-Link network connection.
NOTE
Before proceeding ensure that the MR-J3-D01I/O expansion card is not installed. If it is in-
stalled CC-Link communications will be disabled.
5.1

Additional Connections

In addition to the minimum configuration described in chapter 3.1 you also need to connect the
CC-Link cable and the cabling for connector CN6 for this mode.
200–230V AC
Fig. 5-1:
MR-J3-T
1-phase
Connections for operating the servo amplifier via a CC-Link network
ON
EMG. OFF OFF
Servo amplifier
EMG. OFF
24V DC
24V DC ±10%
800mA
Servo ON
Additional Connections
Servo motor
Motor
Encoder
Encoder cable
24V DC
24V DC ±10%
150mA
Alarm
CC-Link
module
CC-Link cable
V1.10 compatible
5 - 31