Function Pump; Disassembly - JLG 1850SJ Service And Maintenance Manual

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

SECTION 5 - BASIC HYDRAULIC INFORMATION & HYDRAULIC SCHEMATICS
5.8

FUNCTION PUMP

Disassembly

1. Remove the control from the endcap by removing the 4
control bolts (C300), using a 4 mm internal hex wrench.
2. Remove and discard the 4 O-rings (C200).
3. Remove the 4 endcap screws (J030) using a 10 mm
internal hex wrench.
J020
B090
B010
B020
K060
4. Carefully remove the endcap (J020). Prevent the valve
(B090) plate from falling off.
5. Place the endcap and valve plate in a clean area, pro-
tecting them from contamination.
5-150
C200
C300
I4 mm
J030
10 mm
E101 17
6. Remove the bearing cup (B010), bearing cone (B020)
and housing O-ring (K060). Discard the O-ring.
7. Tilt the housing on its side to allow fluid to drain.
8. Remove the cylinder block kit while holding onto the
front shaft.
s
K041
9. Set cylinder block on a clean dry surface.
10. Rotate pump back to a position so that the shaft is
pointing down.
11. Pull the shaft (J010) from the shaft seal.
pJ010
B040
B043
12. Compress the bias spring (B025) and rotate the servo
piston assembly (P020) towards the swashplate (B040).
13. Lift the swashplate/servo piston assembly up at an
angle and remove it from the housing.
P101 368
P020
B025
B044
K030
E101 176
3121619

Advertisement

Table of Contents
loading

Table of Contents