Pressing the ESC key
before calibration is complete will display the CAL FAILED
message. This will not disturb the prior calibration infor-
mation.
7. Press ENTER
. The analyzer screen will read:
8. If the platform is empty, press ENTER
will read:
LOAD SENSI NG:
accessory xxxlbs:
3121619
after starting calibration and
. The screen
SECTION 6 - JLG CONTROL SYSTEM
NOTE: Accessory weight will reset to 0 lbs. each time the machine
is re-calibrated and will need to be re-entered.
NOTE: The Accessory weight will be temporarily stored in the Con-
trol System until calibration has been completed success-
fully.
Refer to Table 6-8, Accessory Weights. Use the up and
down analyzer keys to enter the accessory weight(s) (in
lbs). When all the accessory weights are entered, press
ENTER
. The screen will read:
Table 6-8. Accessory Weights
Accessory
SkyWelder (stick welder)
SkyWelder Prep
SkyCutter (plasma cutter)
SkCutter / SkyWelder Combo
Fire Extinguisher
Overhead SoftTouch
Work Surface
NOTE: Not all Accessories are available on every JLG model.
Some Accessory combinations are prohibited due to
excessive weight and/or load restriction. If any installed
JLG Accessories are labeled with weight decals but are
not listed in the table above, include their weight when
entering the ACC WEIGHT value.
Weight
70 lb (32 kg)
Prep only = 15 lb (7 kg)
Full install = 70 lb (32 kg)
70 lb (32 kg)
140 lb (64 kg)
45 lb (20 kg)
80 lb (36 kg)
20 lb (9 kg)