SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
1655
138
1761
14
1656
138
1761
14
1666
924
524100
9
1672
9-4-2
524118
9
1676
928
524104
9
1683
9-4-5
524121
9
1687
9-4-9
524125
9
1705
972
524156
9
1752
415
2791
7
1753
415
2791
2
3-102
Table 3-10. Engine Fault Codes
Description
The urea tank volume ratio is below the
threshold of <5%
The urea tank volume ratio is below the
threshold of <2.5%
Timeout error of CAN-Transmit-Frame Com-
DPFHisDat.
Timeout error of CAN-Receive-Frame
ComRxCM1
Timeout error of CAN-Receive-Frame Com-
RxDPFCtl. CM1 Module Customer Recieve
Message.
Timeout error of CAN-Receive-Frame Com-
RxTrbChActr
Timeout error of CAN-Receive-Frame Com-
TxTrbChActr
Timeout error of CAN-Receive-Frame
ComRxEBC2 from wheel speed sensor.
EGR actuator is mechanically blocked.
corrupted CAN communication with actua-
tor.
Possible Cause
actual urea tank level SCRUTnk_rVol_mp [%] is
below applicable threshold 5%
actual urea tank level SCRUTnk_rVol_mp [%] is
below 2.5%
Open load on CANBUS wiring.
If the frame CM1 message is not transmitted
successfully
Time out of Check CANBUS EAT Control Receive
Message, PGN65348.
The message is not received.
Timeout Error (Missing CAN Bus message)
Timeout Error (Missing CAN Bus message)
Timeout Error (Missing CAN Bus message)
Defect on wheel speed sensor.
EGR actuator faulty or blocked.
CAN bus error or faulty EGR actuator.
Action
Check urea level => if empty, then fill in urea
Check DEF level sensor.
If there is urea in the tank, then move the floater
of the level sensor. The floater must
be free. If you lift the sensor body, then
SCRUTnk_rVol_mp must change.
Exchange DEF level sensor, if no change of value
or it's implausible.
Check urea level => if empty, then fill in urea
Check DEF level sensor.
If there is urea in the tank, then move the floater
of the level sensor. The floater must
be free. If you lift the sensor body, then
SCRUTnk_rVol_mp must change.
Exchange DEF level sensor, if no change of value
or it's implausible.
Check wiring, component.
Check CAN Bus cabling (Bus sheduling, polarity,
short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Threshold for error detection is an internal ECU
threshold.
Check CANBUS EAT Control Receive Message,
PGN65348.
CM1 Module Customer Recieve Message.
Check CAN Bus cabling (Bus sheduling, polarity,
short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Check CAN Bus cabling (Bus sheduling, polarity,
short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Check CAN Bus cabling (Bus sheduling, polarity,
short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Replace the wheel speed sensor.
Threshold for error detection is an internal ECU
threshold.
Check the EGR actuator and EGR valve to
mechanical blockage / clean.
Check for free movement of the valve. If it'S
blocked, then exchange the EGR valve.
Threshold for error detection is an internal ECU
threshold.
Check other CAN bus components. If no mes-
sage is sent, fix the wiring.
If o.k. exchange EGR actuaror.
3121619