JLG 1850SJ Service And Maintenance Manual page 118

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
140
767
523941
9
141
767
523942
9
142
767
523943
9
168
763
523935
12
169
764
523936
12
171
3-3-3
523212
9
179
527
523240
9
291
119
523776
9
292
119
523777
9
305
118
898
9
360
737
523982
0
361
737
523982
1
3-68
Table 3-10. Engine Fault Codes
Description
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1OGCVol2 information;
factors & Sensorcalibration for NOX Sensor
(SCR-system downstream cat; DPF-system
downstream cat)
Timeout Error (BAM to BAM) for CAN-
Receive-Frame AT1OGCVol2 information,
Calibration message 1 of the after catalyst
NOx sensor has failed.
Factors & Sensorcalibration for NOX Sensor
(SCR-system downstream cat, DPF-system
downstream cat)
Timeout Error (PCK2PCK) for CAN-Receive-
Frame AT1OGCVol2 information; factors &
Sensorcalibration for NOX Sensor (SCR-sys-
tem downstream cat; DPF-system
downstream cat)
Timeout Error of CAN-Transmit-Frame
EEC3VOL1; Engine send messages
Timeout Error of CAN-Transmit-Frame
EEC3VOL2; Engine send messages
Timeout Error of CAN-Receive-Frame
ComEngPrt; Engine Protection
Timeout CAN-message FunModCtl; Func-
tion Mode Control
Timeout Error of CAN-Receive-Frame TSC1TE
- active
Message TSC1-TE has been missing (passive) Passive timeout Error (Missing CAN Bus mes-
Timeout Error of CAN-Receive-Frame TSC1TE
- active
Powerstage diagnosis disabled; Indicating
that battery voltage is not high.
Powerstage diagnosis disabled; Indicating
that battery voltage is not low.
Possible Cause
Timeout Error (Missing CAN Bus message)
Defective Nox sensor, faulty parameterization. NOX downstream sensor and sensor connection
The fault is detected when a timeout error in
packet 2 of NOxSenVol2Rx frame occurs.
Fault is detected if a TimeOut of the EEC3VOL1
frame has occured.
Timeout Error (Missing CAN Bus message)
Timeout Error (Missing CAN Bus message)
Timeout Error (Missing CAN Bus message)
Timeout Error (Missing CAN Bus message)
sage)
Timeout Error (Missing CAN Bus message)
Powerstage diagnostic can be deactivated due
to too high battery voltage.
Powerstage diagnostic can be deactivated due
to too low battery voltage.
Action
NOX downstream sensor and sensor connection
check
check.
NOX downstream sensor and sensor connection
check
Check wiring harness and customer nodes
Check wiring harness and customer nodes
Check wiring harness and customer devices
Check CAN Bus cabling (Bus sheduling, polarity,
short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Threshold for error detection is an internal ECU
threshold.
Check CAN Bus cabling (Bus sheduling, polarity,
short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Check CAN Bus cabling (Bus scheduling, polar-
ity, short circuit, power interrupt), test
protocol of receiver, check CAN functional
range, check actuator
Check CAN Bus cabling (Bus sheduling, polarity,
short circuit, power interrupt), test
protocol of receiver, check CAN functional
range.
Check wiring, check alternator, check cables and
repair or replace if necessary.
Check wiring, check alternator, check cables and
repair or replace if necessary.
3121619

Advertisement

Table of Contents
loading

Table of Contents