JLG 1850SJ Service And Maintenance Manual page 575

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

Flash
DTC
Sequence
Code
6622
6
6
6623
6
6
6629
6
6
6639
6
6
6640
6
6
6641
6
6
680
6
8
681
6
8
810
8
1
813
8
1
814
8
1
815
8
1
8111
8
1
820
8
2
821
8
2
8211
8
2
3121619
Table 6-13. Diagnostic Trouble Code Chart
Fault Message
CANBUS FAILURE - TCU MODULE
CANBUS FAILURE - GATEWAY MODULE
CANBUS FAILURE - TELEMATICS CANBUS
LOADING TOO HIGH
CANBUS FAILURE - JIB CONTROL MODULE
CANBUS FAILURE - JIB LIFT ANGLE SENSOR
CANBUS FAILURE - PLATFORM LEVEL ANGLE
SENSOR
<<< TELEMATICS >>>
REMOTE CONTRACT MANAGEMENT OVER-
RIDE - ALL FUNCTIONS IN CREEP
<<< TILT SENSOR >>>
CHASSIS TILT SENSOR NOT CALIBRATED
CHASSIS TILT SENSOR OUT OF RANGE
CHASSIS TILT SENSOR DISAGREEMENT
CHASSIS TILT READING DISAGREEMENT
<<< PLATFORM LOAD SENSE >>>
LSS CELL #1 ERROR
LSS READING UNDER WEIGHT
Fault Description
Machine Setup/ Telematics=YES, No
device heartbeat for 30 sec
Machine Setup/ Telematics=YES, No
device heartbeat for 30 sec
X
X
The Chassis Tilt Sensor has not been cali-
brated.
Tilt sensor out of range
X
Disagreement between internal (UGM) and
external chassis tilt sensors
LSS has been calibrated and the UGM has
determined that the load sensing system
reading is underweight while a period of
time while operating drive or boom lift up
at speeds greater than creep OR the UGM
has determined that the load sensing sys-
tem reading is less than -1.5 x Gross Plat-
form Weight.
The machine will assume the platform is
overloaded.
This fault, once annunciated is latched
within a given key cycle.
SECTION 6 - JLG CONTROL SYSTEM
Check
-Telematics only
-Telematics only
Check sensor hardware and wiring
Check external/internal sensor hardware and installa-
tion on machine
Ensure platform is not resting on the ground or is not
leveled at an extreme negative angle.
Re-calibrate the load sensing system if the above
items are not a factor.