JLG 1850SJ Service And Maintenance Manual page 117

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

Deutz
Blink
SPN
FMI
Code
Code
99
232
110
0
101
235
111
1
121
341
1109
2
122
591
523698
11
129
596
3224
2
130
597
3224
9
133
766
523938
9
134
766
523939
9
135
766
523940
9
138
114
3234
2
139
117
3234
9
3121619
Table 3-10. Engine Fault Codes
Description
Coolant temperature: the coolant tempera-
ture calculated by ECU is above the target
range.
The ECU activates a system reaction
Coolant level: the coolant level calculated by
ECU is underneath the allowed minimum.
Request of engine shut off: the operator
ignores the engine shut off request within an
allowed period.
Shut off request from supervisory monitor-
ing function
DLC Error of CAN-Receive-Frame AT1IG1Vol
NOX Sensor (SCR-system upstream cat; DPF-
system downstream cat); length of frame
incorrect
Timeout Error of CAN-Receive-Frame
AT1IG1Vol; NOX sensor (SCR-system
upstream cat; DPF-system downstream cat)
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1IGCVol1 information;
factors & Sensorcalibration for NOX Sensor
(SCR-system upstream cat; DPF-system
downstream cat)
Broadcast Announce Message of the calibra-
tion message
of the upstream catalytic NOx sensor has
failed.
Timeout Error (BAM to BAM) for CAN-
Receive-Frame AT1IGCVol1 information.
factors & Sensorcalibration for NOX Sensor
(SCR-system upstream cat, DPF-system
downstream cat).
Timeout Error (PCK2PCK) for CAN-Receive-
Frame AT1IGCVol1 information; factors &
Sensorcalibration for NOX Sensor (SCR-sys-
tem upstream cat; DPF-system
downstream cat)
DLC Error of CAN-Receive-Frame AT1O1Vol
NOX Sensor (SCR-system downstream cat;
DPF-system downstream cat); length of
frame incorrect
Timeout Error of CAN-Receive-Frame
AT1OG1Vol; NOX sensor (SCR-system down-
stream cat; DPF-system downstream cat)
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
Coolant temperature above shut off threshold.
Coolant level too low, leakage in cooling sys-
tem, sensor defective, wiring damaged.
Engine Shut Off demand has been ignored by
the user
Engine Shut Off due to supervisory function
Not Used
Failure of the CAN Bus message
Failure of the CAN Bus message
Defective Nox sensor, faulty parameterization
Failure of the CAN Bus message
Failure of the CAN Bus message
Failure of the CAN Bus message
Action
Clean radiator, check fan drive, check coolant
level, check cooling system in general,
check thermostat function, check water pump
Check coolant level, inspect cooling system for
leakage and if necessary repair it,
check sensor and wiring
Depending on error requested a shut off.
Threshold for error detection is an internal ECU
threshold.
Check error memory for additional errorcode to
find root cause.
Depending on additional error follow the docu-
mented "Take action for repair".
Threshold for error detection is an internal ECU
threshold.
Check Nox-Sensor and the wiring from CAN-
BUS.
NOX sensor and sensor connection check
NOX sensor and sensor connection check
NOX sensor and sensor connection check
NOX sensor and sensor connection check
NOX downstream sensor and sensor connection
check
NOX downstream sensor and sensor connection
check
3-67

Advertisement

Table of Contents
loading

Table of Contents