JLG 1850SJ Service And Maintenance Manual page 141

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

Deutz
Blink
SPN
FMI
Code
Code
1135
669
3031
0
1136
669
3031
1
1137
6-6-9
4365
2
1138
6-6-9
4365
3
1139
6-6-9
4365
4
1157
228
97
12
1170
555
523612
12
3121619
Table 3-10. Engine Fault Codes
Description
The urea tank temperature sensor detects a
value above the maximum allowed thresh-
old
The urea tank temperature sensor detects a
value lower than the minimum allowed
threshold.
Signal error in case of Urea tank temperature
trnasmitted via CAN-signal Com_tUTnkT.
Urea tank temperature sensor: he current
drain measured by ECU is above the target
range.
Urea tank temperature sensor: he current
drain measured by ECU is above the target
range.
Fuel filter water level sensor: the maximum
level is exceeded
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged inter-
nally; no item will be created in error mem-
ory
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
Sensed urea tank temperature > physical range
high limit
sensed urea tank temperature < physical range
low limit
CAN message is not send properly.
Shortcut or open load.
Shortcut or open load.
Water level in fuel pre-filter reservoir over limit
(bad fuel quality)
Error during positive test (ECU internal error).
Diagnostic fault check to report that the
positive test failed
Action
Case "CANBUS sensor":
Check urea tank temperature: really hot?
Check CANBus-message of DEF sensor urea tank
temperature Com_dRxSCR2Byt2
Compare it to Com_dRxSCR1Byt1 (urea tem-
perature at quality sensor) identical?
Tank heater permantly on?
Check wiring of DEF-quality sensor
Case "analog DEF T & Level sensor":
Check urea tank temperature: really hot?
Check urea tank temperature SCR_tSensUTnkT
Compare urea tank temperature to EnvT_t or to
SCR_tSMT (the urea temperature
inside the supply module) identical?
Tank heater permantly on?
Check wiring of analog DEF T & Level sensor
Case "CANBUS sensor":
Check ambient temperature EnvT_t => About
-40 °C? If yes Error could be plausible
Check CANBus-message of DEF sensor urea tank
temperature Com_dRxSCR2Byt2
Compare it to Com_dRxSCR1Byt1 (urea tem-
perature at quality sensor) identical?
Check wiring of DEF-quality sensor
Check quality sensor
Case "analog DEF T & Level sensor":
Check urea tank temperature: really that cold?
Check ambient temperature EnvT_t =>
About -40 °C? If yes Error could be plausible
Check urea tank temperature SCR_tSensUTnkT
Check wiring of analog DEF T & Level sensor
Check analog DEF T & Level sensor
Check sensor connector
Check CANbus
Threshold for error detection is an internal ECU
threshold.
The Sensed raw voltage value SCR_uRawUTnkT
is below SCR_SRCUTnkT.uMax_C.
Check wiring.
Threshold for error detection is an internal ECU
threshold.
The sensed raw voltage value SCR_uRawUTnkT
is above SCR_SRCUTnkT.uMin_C.
Check wiring.
Measure Voltage at Water in Fuel Sensor and
renew harness if needed.
Threshold for error detection is an internal ECU
threshold.
Reflash ECU. If error is still activ replace ECU.
3-91

Advertisement

Table of Contents
loading

Table of Contents