SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
1092
674
4345
3
1093
674
4345
4
1094
673
4343
5
1096
673
4343
3
1097
673
4343
4
1098
676
523718
5
1100
676
523718
3
1101
676
523718
4
1102
675
4341
5
1104
675
4341
3
1105
675
4341
4
3-88
Table 3-10. Engine Fault Codes
Description
Urea backflow line heater: the current drain
measured by ECU is above the target range
Urea backflow line heater: the current drain
measured by ECU is above the target range
Urea pressure line heater: the current drain
measured by ECU is above the target range
Urea pressure line heater: the current drain
measured by ECU is above the target range
Urea pressure line heater: the current drain
measured by ECU is above the target range
Urea heater relay: the current drain mea-
sured by ECU is above the target range
Urea heater relay: the current drain mea-
sured by ECU is above the target range
Urea heater relay: the current drain mea-
sured by ECU is above the target range
Urea heater supply line: the current drain
measured by ECU is above the target range
Urea heater supply line: the current drain
measured by ECU is above the target range
Urea heater supply line: the current drain
measured by ECU is above the target range
Possible Cause
Shortcut to battery
If this error detected during the heating phase is
a result error: KWP 1089
Short cut to battery or broken wiring, broken
heating element in backflow line
Shortcut to ground
If this error detected during the heating phase is
a result error: KWP 1089
Short cut to ground or broken wiring, broken
heating element in backflow line
Open load
If this error detected during the heating phase is
a result error: KWP 1089
Broken wiring, broken heating element in pres-
sure line
shortcut to battery
If this error detected during the heating phase is
a result error: KWP 1089
broken heating element in pressure line
Shortcut to ground
If this error detected during the heating phase is
a result error: KWP 1089
Short cut to ground or broken wiring, broken
heating element in pressure line
Open load
If this error detected during the heating phase it
is a result error: KWP 1089
Broken wiring
broken relay
Shortcut to battery
If this error detected during the heating phase it
is a result error: KWP 1089
Broken wiring, broken relay
Shortcut to ground
If this error detected during the heating phase it
is a result error: KWP 1089
Broken wiring, broken relay
electrical error
electrical error
electrical error
Action
Threshold for error detection is an internal ECU
threshold
Check wiring
Check heating element
Threshold for error detection is an internal ECU
threshold
Check wiring
Check heating element
Threshold for error detection is an internal ECU
threshold
Check wiring
Check heating element
Threshold for error detection is an internal ECU
threshold
Check wiring
Check heating element
Threshold for error detection is an internal ECU
threshold
Check wiring
Check heating element
Threshold for error detection is an internal ECU
threshold
Test SCR main relay
Check cabling, if necessary replace relay.
Threshold for error detection is an internal ECU
threshold
Check wiring
Check SCR main relay
Threshold for error detection is an internal ECU
threshold
Check wiring
Check SCR main relay
Threshold for error detection is an internal ECU
threshold
Check wire harness
Check supply line
Threshold for error detection is an internal ECU
threshold
Check wire harness
Check supply line
Threshold for error detection is an internal ECU
threshold
Check wire harness
Check supply line
3121619