SECTION 6 - JLG CONTROL SYSTEM
Message Displayed on
Analyzer
TEST ALL INPUTS?
TESTS COMPLETE
6-60
Table 6-6. System Test Messages
Message Displayed on
Analyzer
CLOSE XXXXXXX
OPEN XXXXXXX
XXXXXXX XXXXXXX TO MAX
XXXXXXX XXXXXXX TO MIN
PUMP POT TO MAX
PUMP POT TO MIN
MULTIPLE CLOSURE
Prompts whether to check every operator input. If ESC is pressed or clicked, the system test ends.
If ENTER is pressed or clicked, each operator input is prompted for in turn.
In platform mode every platform switch and joystick is tested.
In ground mode every ground switch is tested.
NOTE: Tower lift switches are not tested if TOWER LIFT=NO. Tower telescope switches are not
tested if TOWER TELE=NO. Jib switches are not tested if JIB = NO. Extendable axle switches are
not tested if EXT AXLES=NO. Four wheel steer switches are not tested if 4WS=NO.
NOTE: Left/right jib switches are not tested unless JIB = SIDESWING.
Prompts displayed during the operator input test below messages.
The named switch should be closed.
The named switch should be opened.
The named joystick should be pushed to its full extent in the named direction.
The named joystick should be returned to neutral from the named direction.
The pump pot should be turned to maximum.
The pump pot should be turned to minimum.
More than one operator input is closed; if only one has been operated, there could be a short
between two inputs.
Indicates that the system test is complete. Any problems reported should have been noted and
should now be rectified. Press ESC/CANCEL to return to the RUN SYSTEM TEST Analyzer menu.