JLG 1850SJ Service And Maintenance Manual page 563

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

Flash
DTC
Sequence
Code
212
2
1
213
2
1
220
22
0
227
2
2
2211
2
2
2212
2
2
2213
2
2
2215
2
2
2216
2
2
2217
2
2
2218
2
2
2219
2
2
2220
2
2
2221
2
2
2222
2
2
2223
2
2
2224
2
2
230
2
0
23124
2
3
23125
2
3
23126
2
3
23127
2
3
3121619
Table 6-13. Diagnostic Trouble Code Chart
Fault Message
KEYSWITCH FAULTY
FSW FAULTY
<<< PLATFORM CONTROLS >>>
STEER SWITCHES FAULTY
FSW INTERLOCK TRIPPED
DRIVE LOCKED - JOYSTICK MOVED BEFORE
FOOTSWITCH
STEER LOCKED - SELECTED BEFORE FOOT-
SWITCH
D/S JOY. OUT OF RANGE LOW
D/S JOY. OUT OF RANGE HIGH
D/S JOY. CENTER TAP BAD
L/S JOY. OUT OF RANGE LOW
L/S JOY. OUT OF RANGE HIGH
L/S JOY. CENTER TAP BAD
LIFT/SWING LOCKED - JOYSTICK MOVED
BEFORE FOOTSWITCH
WAITING FOR FSW TO BE OPEN
FUNCTION SWITCHES LOCKED - SELECTED
BEFORE ENABLE
FOOTSWITCH SELECTED BEFORE START
<<<Ground Inputs >>>
LIFT PRESSURE SENSOR - OUT OF RANGE
LOW
LIFT PRESSURE SENSOR - OUT OF RANGE
HIGH
LIFT PRESSURE SENSOR - NOT DETECTING
CHANGE
LIFT CYLINDER - OVER PRESSURE
Fault Description
Both Platform and Ground modes are
selected simultaneously.
Both Footswitches are closed for more then
one second.
Both Steer Left and Steer Right inputs are
closed simultaneously.
The Footswitch was closed for more then
seven seconds.
A drive function was selected with Foot-
switch open.
A steer function was selected with Foot-
switch open.
The D/S Joystick reference volt- age is low.
The D/S Joystick reference volt- age is >
8.1V.
The D/S Joystick center tap volt- age is <
3.08V or > 3.83V.
The L/S Joystick reference volt- age is low.
The L/S Joystick reference volt- age is >
8.1V.
The L/S Joystick center tap volt- age is <
3.08V or > 3.83V.
A lift / swing function was selected with
Footswitch open.
The Footswitch was closed during Platform
selection.
A boom function was selected with Foot-
switch open.
The Footswitch was closed during engine
start.
Pressure transducer sensor voltage output
< 0.4V for 240ms
Pressure transducer sensor voltage output
> 4.5V for 240ms
Lift down is commanded and pressure does
not change by 20psi within 10seconds. This
is only evaluated when rod-side pressure
starts out below a threshold value
At the end of a lift up event if pressure is
greater than 2200 psi for 3seconds
SECTION 6 - JLG CONTROL SYSTEM
Check
- Can be reported during power- up.
- Can be reported during power- up.
- Resistive joysticks, these faults do not occur.
- Resistive joysticks.
- If the reference voltage is > 7.7V then the reference
voltage is out of tolerance of a short to battery has
occurred.
- Resistive joysticks.
- There is a +/- .1V range. around these values due to
resistor tolerances
- Resistive joysticks, these faults do not occur.
- Resistive joysticks.
- If the reference voltage is > 7.7V then the reference
voltage is out of tolerance of a short to battery has
occurred.
- Resistive joysticks.
- There is a +/- .1V range. around these values due to
resistor tolerances
- Can be reported during power- up.
Check sensor hardware and wiring
Check sensor hardware and wiring
Check sensor hardware and wiring
Check lift cylinder seal across piston, fault detects a
hardware failure
6-131

Advertisement

Table of Contents