SECTION 4 - BOOM & PLATFORM
Use the Left
or Right
Press Enter
. Once Enter
or Down
arrow key will turn the boom recovery
on or off. Once turned on, main boom lift down will be
enabled and main telescope in will be enabled to recover the
boom. After the boom is brought down it will be trapped into
transport. Reset or turning it off is achieved by escaping out of
the service mode, by cycling power to the machine, or re-
entering the service mode and manually turning it off.
4-6
arrow key until you see:
is pressed using the Up
4.2 BOOM REMOVAL AND INSTALLATION
Removal
1. If necessary, remove the platform.
2. If necessary, remove the jib.
3. Tag and disconnect hoses T2 T3, 7, 8, and Pressure Filter
lines from the main valve. Cap or plug all openings.
3121619