JLG 1850SJ Service And Maintenance Manual page 516

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
8. This completes the Jib Level Up crackpoint procedure.
Press ESC
to return to the calibrations menu.
9. Scroll to JIB LVL DN CRKPT and press ENTER
6-84
10. Press ENTER
point.
NOTE: Have an assistant help verify that movement occurs.
.
11. Using the analyzer, press and hold the Up Arrow
until the function starts moving, then press ENTER
. Release the Up Arrow
to calibrate Jib Level Down crack-
.
3121619