DTC
Sequence
Code
8495
8
4
8496
8
4
8497
8
4
8498
8
4
8499
8
4
84100
8
4
84101
8
4
84102
8
4
84103
8
4
84104
8
4
84105
8
4
84106
8
4
84107
8
4
84108
8
4
3121619
Table 6-13. Diagnostic Trouble Code Chart
Fault Message
TURN TABLE SENSOR #1 - FREQUENCY OUT
OF RANGE LOW
TURN TABLE SENSOR #1 - FREQUENCY OUT
OF RANGE HIGH
TURN TABLE SENSOR #2 - FREQUENCY OUT
OF RANGE LOW
TURN TABLE SENSOR #2 - FREQUENCY OUT
OF RANGE HIGH
CHASSIS TURN TABLE SENSORS - DISAGREE-
MENT
CHASSIS TURN TABLE SENSORS AND DRIVE
ORIENTATION SWITCH - DIS- AGREEMENT
CHASSIS TURN TABLE SENSORS - NOT CALI-
BRATED
MAIN CYLINDER ANGLE SENSOR - NOT
DETECTING CHANGE
JIB LEVEL ANGLE SENSOR - NOT DETECTING
CHANGE
JIB LIFT ANGLE SENSOR - NOT DETECTING
CHANGE
PLATFORM LEVEL ANGLE SENSOR - NOT
DETECTING CHANGE
JIB LEVEL MOVEMENT WITHOUT COMMAND
JIB LIFT MOVEMENT WITHOUT COMMAND
PLATFORM LEVEL MOVEMENT WITHOUT
COMMAND
SECTION 6 - JLG CONTROL SYSTEM
Fault Description
Check
6-151