SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
1036
683
4768
2
1039
683
4765
0
1040
683
4765
0
1044
683
4768
3
1045
683
4768
4
3-86
Table 3-10. Engine Fault Codes
Description
Static plausibility check:
The exhaust temperature value from the
sensor before DOC, the exhaust temperature
value from the sensor after DOC, the temper-
ature value from the sensor before
SCR-Cat, the environment temperature and
the coolant engine temperature their ratios
to each other exceed their related thresh-
olds.
Dynamic plausibility check with environ-
ment temperature sensor value:
The exhaust temperature value from the
sensor before DOC is lower than an applica-
ble environment temperature threshold
The exhaust temperature value from the
sensor befor DOC
is above an applicable upper shutoff thresh-
old
TOxiCatUs_tShOffThresHiAds_C = Thresh-
old 1 in Normal and
Heatmodes
(TOxiCatUs_tShOffThresHiRgn_C = Thresh-
old 2
in stand-still)
The exhaust temperature value from the
sensor befor DOC
is above an applicable upper warning
threshold
TOxiCatUs_tWarnThresHi_C = Threshold
Oxidation catalyst upstream temperature
sensor: the voltage of sensor measured by
ECU is out of the target range
Oxidation catalyst upstream temperature
sensor: the voltage of sensor measured by
ECU is out of the target range
Possible Cause
Static plausibility check:
The exhaust temperature value from the sensor
before DOC, the exhaust temperature
value from the sensor after DOC, the tempera-
ture value from the sensor before
SCR-Cat, the environment temperature and the
coolant engine temperature their ratios
to each other exceed their related thresholds.
(difference between temperature after DOC and
temperature before DOC > Threshold 1
difference between temperature befor DOC and
before SCR > Threshold 2
difference between temperature after DOC and
before SCR < Threshold 3
difference between temperature after DOC and
ambinet temperature < Threshold 4
differnece between temperatur ambient tem-
perature and engine temperature <
Threshold 5)
Dynamic plausibility check with environment
temperature sensor value:
The exhaust temperature value from the sensor
before DOC is lower than an applicable
environment temperature threshold (< envi-
ronmental temperature + Threshold 6)
sensed temperature upstream DOC > shut-off
limit
Sensed temperature upstream DOC > warning
limit
The sensed raw voltage value
Exh_uRawTOxiCatUs is above
Exh_SRCTOxiCatUs.uMax_C
Shortcut to battery
The sensed raw voltage value
Exh_uRawTOxiCatUs is
below Exh_SRCTOxiCatUs.uMin_C
Shortcut to ground
Action
Check ambient temperature => value plausi-
ble?
upstream DOC sensor mounted within exhaust
line?
T upstream DOC sensor physically mounted in
correct position upstream DOC? (not
upstream SCR or downstream DOC?)
Check T upstream DOC sensor
Check other T-sensors within EAT-system
(Exh_tOxiCatDs & UCatUsT_tFlt_mp show
plausible values? No errors on them?
Check air path of engine: EGR-Valve, Intake-
Throttle,
Check Turbocharger and Piping each for leakage
and correct function
Check injectors: is an injector got stuck?
Exchange temperature sensor upstream DOC
Check air path of engine: EGR-Valve, Intake-
Throttle, Turbocharger and Piping each
for leakage and correct function
Check injectors: is an injector got stuck?
Exchange temperature sensor upstream DOC
Check wiring harness to temperature sensor
upstream DOC
Exchange temperature sensor upstream DOC
Check wiring harness to temperature sensor
upstream DOC
Exchange temperature sensor upstream DOC
3121619