JLG 1850SJ Service And Maintenance Manual page 123

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

Deutz
Blink
SPN
FMI
Code
Code
585
163
656
3
592
135
523615
5
593
135
523615
12
594
135
523615
3
595
135
523615
4
596
135
523615
3
597
135
523615
4
612
555
523612
12
613
555
523612
12
614
555
523612
12
615
555
523612
12
3121619
Table 3-10. Engine Fault Codes
Description
Injector cyl. 6: the current drop measured by
ECU is above the target range
Detecting an open load fault in the metering
unit
powerstage of metering unit is overheated
Fuel metering unit: the current drain mea-
sured by ECU is above the target range
Fuel metering unit: the current drain mea-
sured by ECU is above the target range
Fuel metering unit: the current drain mea-
sured by ECU is above the target range
Fuel metering unit: the current drain mea-
sured by ECU is above the target range
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged inter-
nally; no item will be created in error mem-
ory.
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged inter-
nally; no item will be created in error mem-
ory
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged inter-
nally;
no item will be created in error memory
Internal hardware monitoring: the CPU of
the ECU is reset and the cause is logged inter-
nally;
no item will be created in error memory
SECTION 3 - CHASSIS & TURNTABLE
Possible Cause
Suspected Components:
injector cylinder 6
wiring harness, cable break or short circuit, sen-
sor defective, connection cable
wiring harness defective, cable break
over temperature
short circuit to battery high side
short circuit to ground high side
short circuit to battery low side
short circuit to ground low side
Plausibility check failed (MoCADC_uNTP_mp is
higher than MoCADC_uNTPMax_C).
Analysis of test voltage (Value is out of the tar-
get -> ECU internal error)
Analysis of the ratiometric correction (Value is
out of the target -> ECU internal error)
Error report due to an error in the plausbility of
Function Coordination(FC) and
Monitoring Modul(MM)(ECU internal error)
Action
Threshold for error detection is an internal ECU
threshold.
Check wiring harness, injectors and if necessary
repair/replace it. Use SerDia Injector
test for diagnosis.
Threshold for error detection is an internal ECU
threshold.
Check wiring harness and metering unit if nec-
essary repair/replace it.
Threshold for error detection is an internal ECU
threshold.
Check functionality of metering unit and
replace it if needed.
Check temperature of metering unit and
improve the installation in case of overheating.
Threshold for error detection is an internal ECU
threshold.
Check wiring harness and metering unit if nec-
essary repair/replace it.
Threshold for error detection is an internal ECU
threshold.
Check wiring harness and metering unit if nec-
essary repair/replace it.
Threshold for error detection is an internal ECU
threshold.
Check wiring harness and metering unit if nec-
essary repair/replace it.
Threshold for error detection is an internal ECU
threshold.
Check wiring harness and metering unit if nec-
essary repair/replace it.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
Check wiring, check connected sensors actua-
tors.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
Check wiring, check connected sensors actua-
tors.
If error is still present, exchange ECU.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
3-73