JLG 1850SJ Service And Maintenance Manual page 587

Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

Flash
DTC
Sequence
Code
84154
8
4
850
8
5
851
8
5
852
8
5
855
8
5
857
8
5
3121619
Table 6-13. Diagnostic Trouble Code Chart
Fault Message
BOOM LENGTH SENSOR 2 FAULTY
<<< MOMENT / LOAD PINS >>>
MOMENT PIN - HORIZONTAL FORCE OUT OF
RANGE
MOMENT PIN - VERTICAL FORCE OUT OF
RANGE
MOMENT PIN - SENSOR FAULT
NEW MOMENT PIN DETECTED
Fault Description
There are three ways (a, b, c) that these
faults can be set:
(a)
If the length sensor voltage changes more
than 0.0168 volts within 40 milliseconds a
counter for the respective length sensor
shall be incremented to aid service in diag-
nosing bad sensor performance. The coun-
ter below shall be incremented anytime the
description above is met. It is cleared/reset
by a power cycle
BmLenSnsr(1/2)FaultCounter_PowerCycle
> 30
(b)
The counter below shall be incremented
every time BmLenSnsr(1/
2)FaultCounter_PowerCycle (described
above) reached its threshold. This value is
stored in EEPROM in order to track the his-
tory of the issue. (A successful Boom Sensor
Calibration will reset this counter – this is
reflected in the boom sensor calibration
document)
BmLenSnsr(1/2)FaultCounter_EEPROM >
3
(c)
The fault counter below shall be incre-
mented every time the trigger condition
described in section (a) is observed during
certain steps during Boom Sensor Calibra-
tion (please see that document section for
further details)
BmLenSnsr(1/2)FaultCounter_BmSnsrCal
> 20
If (a) or (b) or (c) are met (fault triggered)
the machine will be put into Electrical
Retrieval
Fault, once triggered, is maintained within
a given key-cycle
Machine will be trapped in transport
The Moment Pin horizontal force is out of
range.
The Moment Pin vertical force is out of
range.
The Moment Pin has reported a fault.
A new Moment Pin has been detected.
SECTION 6 - JLG CONTROL SYSTEM
Check
Check wiring and hardware
6-155