SECTION 3 - CHASSIS & TURNTABLE
Deutz
Blink
SPN
FMI
Code
Code
861
134
523613
1
862
134
523613
0
864
134
523613
2
876
146
523470
7
877
147
157
3
878
147
157
4
925
148
523720
8
926
148
523720
8
927
689
523721
11
928
928
691
8
3-80
Table 3-10. Engine Fault Codes
Description
Rail pressure: the fuel pressure in rail calcu-
lated by ECU is below the target range
which is dependant on the engine speed.
Rail pressure: the fuel pressure in rail calcu-
lated by ECU is above the target range.
Rail pressure metering unit, Setpoint of
metering unit in overrun mode not plausi-
ble.
Rail pressure is out of the expected average
range.
Rail pressure sensor: the voltage of sensor
measured by ECU is out of the target range.
Rail pressure sensor: the voltage of sensor
measured by ECU is out of the target range.
Supply module heater: Duration of switch on
is too long.
Supply module heater: Dutycycle timing
over error threshold.
Supply module heater: temperature mea-
surement not available.
Supply module heater: PWM time periode
out of valid range.
Possible Cause
Rail pressure falls below the limiting value
based on the engine speed.
Rail pressure exceeds the limiting value.
Pressure pump delivery quantity in overrun
exceeds the threshold based on the
pressure.
Rail pressure is out of the expected average
range.
PRV can not be opened.
Short cut to battery.
Damaged rail pressure sensor.
Check cabling, check rail pressure sensor and if
necessary replace it,
check connection cable and if necessary repair
or replace it.
uty cycle for temperature readout from supply
module heater to the control unit is out
of range; Supply modul defect, fault in the wir-
ing.
Duty cycle for temperature readout from supply
module heater to the control unit is not
valid.
Supply modul defect, fault in the wiring.
Duty cycle for temperature readout from supply
module heater to the control unit is not
available.
Supply modul defect, fault in the wiring.
PWM signal for temperature readout from sup-
ply module to the control unit is out of
range.
Supply modul defect, fault in the wiring.
Action
Threshold for error detection is an internal ECU
threshold.
(A) Check backflow pressure
(B) Check Injector function with SerDia
(C) Change components (metering unit, injec-
tor) if necessary
(A) Check backflow pressure
(B) Check pressure relief valve and metering
unit.
(C) Change components if necessary
Threshold for detection is an internal ECU
threshold.
(A) Check backflow pressure
(B) Check pressure relief valve and metering
unit.
(C) Change components if necessary
(A) Check railpressure relief valve and replace if
necessary.
(B) Check high pressure pumps, pressure relief
valve and metering unit.
(C) Change components if necessary
Check cabling, check rail pressure sensor and if
necessary replace it,
check connection cable and if necessary repair
or replace it.
Check cabling, check rail pressure sensor and if
necessary replace it,
check connection cable and if necessary repair
or replace it.
When the received supply module heater tem-
perature duty cycle SCR_rSMT is out of
the failurerange (SCR_rSMFailMax_C <
SCR_rSMHtrT < SCR_rSMFailMin_C)
Supply module check and replace if necessary.
Check the wiring.
When the received supply module heater duty
cycle SCR_rSMHtrT is in the valid range
(SCR_r-
Supply module check and replace if necessary.
Check the wiring.
Threshold for detection is an internal ECU
threshold.
No erasing in the current driving cycle.
Supply module check and replace if necessary.
Check the wiring.
The Time period of the received PWM signal
SCR_tiSMPerPwm is within the specified
range of150ms to 250ms
Supply module check and replace if necessary.
Check the wiring.