Huawei NetEngine40E Hardware Description page 486

Hide thumbs Also See for NetEngine40E:
Table of Contents

Advertisement

HUAWEI NetEngine40E Universal ServiceRouter
Hardware Description
Figure 6-165 Appearance of the 2-port 10GBase LAN/WAN-XFP+24-Port 100/1000Base-X-SFP
LPUS
Panel
Figure
100/1000Base-X-SFP LPUS.
Figure 6-166 Panel appearance of the 2-port 10GBase LAN/WAN-XFP+24-Port
100/1000Base-X-SFP LPUS
Table 6-462 Indicators on the panel of the 2-port 10GBase LAN/WAN-XFP+24-Port
100/1000Base-X-SFP LPUS
Indicator
OFL button
OFL indicator
(red)
RUN (green)
L/A (green)
Interface Attributes
Table 6-463
100/1000Base-X-SFP LPUS.
Issue 01 (2012-09-30)
6-166shows the panel appearance of the 2-port 10GBase LAN/WAN-XFP+24-Port
Table 6-462
Description
It is an OFL button. Before removing a board, press the OFL button.
Hold the button for five seconds till the OFL indicator is on. Then, the
board can be pulled out.
If the indicator is steady on, it indicates that you can remove the
board.
If the indicator blinks once every 2s (0.5 Hz), it indicates that the
system is running normally. If the indicator blinks twice every 1s (2
Hz), it indicates that the system is in the alarm state.
If the indicator is steady on, it indicates that the link is normal. If the
indicator blinks, it indicates that data is being transmitted. If the
indicator is off, it indicates that the link is Down.
lists the interface attributes of the 2-port 10GBase LAN/WAN-XFP+24-Port
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
describes the indicators on the panel.