Huawei NetEngine40E Hardware Description page 411

Hide thumbs Also See for NetEngine40E:
Table of Contents

Advertisement

HUAWEI NetEngine40E Universal ServiceRouter
Hardware Description
Panel
Table 6-346
Table 6-346 Indicators on the panel of the 2-Port 10GBase LAN/WAN-XFP Flexible Card
A(Supporting 1588v2)
Indicator
STATUS
indicator (green)
LINK/ACT
indicator(green)
Interface Attributes
Table 6-347
A(Supporting 1588v2).
Table 6-347 Interface attributes of the 2-Port 10GBase LAN/WAN-XFP Flexible Card
A(Supporting 1588v2)
Attributes
Connector type
Optical
interface
attributes
Working mode
Frame format
Network
protocol
Table 6-348 Attributes of 10G XFP optical modules
Attributes
Maximum
transmission
distance
Center
wavelength
Minimum
transmitting
power
Issue 01 (2012-09-30)
describes the indicators on the panel.
Description
If the indicator blinks once every 2s (0.5 Hz), the FPIC is in the
normal state state. If the indicator blinks twice every 1s (2 Hz), the
FPIC is in the alarm state.
If the indicator is on, the link is Up. If the indicator is blinking, the
data is being read or written. If the indicator is off, the link is Down.
lists the interface attributes of the 2-Port 10GBase LAN/WAN-XFP Flexible Card
Description
LC/PC
Compliant with the selected XFP optical module. (for the attributes of
XFP modules, see
Full-duplex
Ethernet_II, Ethernet_SAP, and Ethernet_SNAP
IP
Description
0.3 km ( 0.19
mi. )
850 nm
-7.3 dBm
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Table
6-348)
10 km ( 6.21
40 km ( 24.86
mi. )
mi. )
1310 nm
1550 nm
-6.0 dBm
-1.0 dBm
6 Boards
80 km ( 49.71
mi. )
1550 nm
0 dBm
397