4 Configuration

4.2 Positioner Interface IRBP B/D

4.2 Positioner Interface IRBP B/D
General
This section describes the I/O configuration for positioner IRBP B/D.
I/O board Configuration for positioner
Address
-
Internal
bus
1) The number relates to the drive module where the I/O board is located, the
example shows DM1.
Simulated outputs for B_POS_SIM
Simulated outputs
UnitMap
0
1
2
Simulated inputs
UnitMap
0
1
2
I/O-Signals configuration for DRIVO_1
Digital outputs TB4
Output
1
2
3
4
5
6
7
8
9
Continues on next page
152
Name
Type
B_POS_SIM
Simulated digit-
al I/O
1
DRIVO_1
Digital I/O
Name
soACT_STN1
soACT_STN2
soACT_INTCH
Name
siSTN1_ACT
siSTN2_ACT
si_INTCH_ACT
UnitMap
Name
0
doACT_K1
1
doACT_K2
2
doACT_K3
3
doACT_K4
4
doACT_K5
5
doACT_K11
6
doACT_K12
7
doACT_K13
8
doACT_K14
© Copyright 2010-2020 ABB. All rights reserved.
Digit-
Digit-
Ana-
al/Input
al/Out-
log/In-
put
put
7
12
-
Description
Activate mechanical unit 1
Activate mechanical unit 2
Activate mechanical unit 3
Description
Mechanical unit 1 activated
Mechanical unit 2 activated
Mechanical unit 3 activated
Description
Activate mechanical unit 1
Activate mechanical unit 2
Activate mechanical unit 3
Activate mechanical unit 4
Activate mechanical unit 5
Activate release break 1
Activate release break 2
Activate release break 3
Activate release break 4
Product manual - IRBP /D2009
3HAC037731-001 Revision: T
Ana-
Re-
log/Out-
lay/Out-
put
put
-
-
Connected to
unit
Positioner
Positioner
Positioner
Positioner
Positioner
Positioner
Positioner
Positioner
Positioner

Hide quick links: