Electrical Assembly Irbp - ABB IRBP Product Manual

Table of Contents

Advertisement

3 Installation and commissioning

3.6.2 Electrical assembly IRBP

3.6.2 Electrical assembly IRBP
Connections
Positioner types A/B/C/D/K/R
Connection of the signals/media is made through the connection flanges.
1
2
3
4
Current collectors
xx0900000990
1
2
Continues on next page
116
Action
Connect the electrical signals (1).
Suitable plugs are supplied for fitting on the incom-
ing cables. See Circuit diagram.
Connect the ground connection (weld negative,
(2)). The positioner chassis is to be separated
from the system ground; eg cable screen.
Connect the air (3) to the connections.
On the rotary unit, there is a free cable/hose for
connection to the fixture.
Current collector connection 1
Current collector connection 2
© Copyright 2010-2020 ABB. All rights reserved.
Note
3
1
3
xx1800003051
1
Electrical signals
2
Ground connection, weld
negative
3
Air connection (4 pcs)
Product manual - IRBP /D2009
3HAC037731-001 Revision: T
2