Expert Parameters; General Parameters - Carl Valentin DYNACODE II IP53 Operating Manual

Ingress protection version
Hide thumbs Also See for DYNACODE II IP53:
Table of Contents

Advertisement

Dynacode II IP
Printhead down time
Ribbon motor early
start time
Ignore empty lines
Set print offset to
minimum
Ribbon saving
mode SHIFT
03.21

10.14.3 Expert Parameters

This is used from ribbon saving algorithm for the calculation of start
time of printhead downwards movement.
This value is added to the acceleration time of transfer ribbon
movement. Time indication for the time between 'motor reached
material speed' and 'printhead burns'.
If the same value is entered as for PhDownT, the printhead upwards
movement is not started before the transfer ribbon motor reached the
material speed.
In the default operation, the printing system stops for the entire layout
length until a new layout can be printed, even if the layout is mainly
empty. As some label programs do not provide any layout length,
issues may occur in connection with the number of cycles, as the
layout length remains constant despite varying lengths of the range to
be printed. With this option, all empty lines can be ignored in the
beginning, at the end or both.
Quick selection to set the print offset to the smallest possible value.
On: The print offset value is reset to the smallest possible value.
Off: The value remains at the preset print offset value.

10.14.4 General Parameters

Layout data can be printed several times laterally displaced. A
maximum utilisation of transfer ribbon can be achieved.