Function Menu
Transfer ribbon
Print offset
Min. distance
between prints
76
Selection of transfer ribbon in meters that is used. Standard, Fast and
Low indicate the tightening force with which the transfer ribbon is
wound up.
Standard (Std) = used for normal transfer ribbon (for KCE
printheads).
Low = is selected if the transfer ribbon was torn in Standard mode or
the transfer ribbon can no longer be removed from the cassette. The
transfer ribbon is not accelerated as much as with Standard and
therefore it is also suitable when using thin transfer ribbon.
Fast = the transfer ribbon is accelerated faster and therefore a higher
number of cycles can be achieved. It can occur that the transfer
ribbon can no longer be removed from the cassette. To avoid this, an
optional cassette is available on request.
Indication of distance of the layout (res. the first layout in case more
layouts per cycles are to be printed) to the zero point of machine.
Settings possible either in mm or ms.
Value range: 1 ... 999 mm
The smallest possible distance between two prints with full ribbon
saving (the print offset must be set to the minimum value). As basis
for the calculation the set ribbon saving parameters are used, as well
as mode and especially the indicated max. print speed.
A detailed description can be found on page 151.