Dynacode II IP
Error message
30
Application
Identifier
31
HIBC definition
32
System clock
33
No CF interface
34
No print memory
35
Printhead open
36
BCD invalid format
37
BCD overflow
38
BCD division
39
FLASH ERROR
40
Length command
41
No drive
42
Drive error
43
Unformatted
44
Delete directory
45
Invalid path
03.21
Cause
Selected application identifier is
not available in GS1-128.
Missing HIBC system sign.
Missing primary code.
Real Time Clock function is
selected but the battery is
empty.
Defective RTC.
Interrupted connection CPU -
CF card.
Defective CF card interface.
Not enough print memory
available.
At start of a print order the
printhead is open.
BCD error
Invalid format for the
calculation of Euro variable.
BCD error
Invalid format for the
calculation of Euro variable.
BCD error
Invalid format for the
calculation of Euro variable.
Flash component error.
Invalid length of the received
command statement.
CF card not found / not
correctly inserted.
Impossible to read CF card
(faulty).
CF Card not formatted.
Attempt to delete the actual
directory.
Too long indication of path.
Operating Manual
Error Correction
Remedy
Check code data.
Check definition of HIBC code.
Change battery.
Change RTC component.
Check connection CPU - CF
card interface.
Check CF card interface.
Check CF assembly on CPU.
Close the printhead and start
print order anew.
Check entered format.
Check entered format.
Check entered format.
Run a software update.
Change CPU.
Check data sent.
Check connection PC - printer.
Insert CF card correctly.
Check CF card, if necessary
change it.
Format CF card.
Change directory.
Indicate a shorter path.