5.17.3 Reverse rotation prevention selection (Pr. 78)

This function can prevent reverse rotation fault resulting from the incorrect input of the start signal.
Parameter
Name
Number
Reverse rotation prevention
78
selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 167)
Set this parameter when you want to limit the motor rotation to only one direction.
This parameter setting has higher priority than the
command from the communication.

5.17.4 Extended parameter display and user group function (Pr. 160, Pr. 172 to Pr. 174)

Parameter which can be read from the operation panel can be restricted.
Parameter
Name
Number
160
User group read selection
∗3, ∗4
User group registered
172
∗1
display/batch clear
173
User group registration
∗1, ∗2
174
User group clear
∗1, ∗2
∗1
This parameter can be set when Pr. 160 User group read selection = "0".
∗2
The values read from Pr. 173 and Pr. 174 are always "9999".
∗3
Pr. 501 can always be read regardless of the Pr. 160 User group read selection setting.
∗4
This parameter allows its setting to be changed during operation in any operation mode even if "0 (initial value) or 1" is set in Pr. 77 Parameter write
selection.
(1)
Display of simple mode parameters and extended parameters (Pr. 160)
When Pr. 160 = "9999", only the simple mode parameters can be displayed on the operation panel. (Refer to the parameter
list , page 78, for the simple mode parameters.)
In the initial setting (Pr. 160 = "0") status, simple mode parameters and extended parameters can be displayed.
REMARKS
Every parameter can be read regardless of the Pr.160 setting when reading parameters through FL remote communication.
(2)
User group function (Pr. 160, Pr. 172 to Pr. 174)
The user group function is designed to display only the parameters necessary for setting.
From among all parameters, 16 parameters maximum can be registered in the user group. When Pr. 160 is set to "1", only
the parameters registered to the user group can be accessed. (The parameters not registered in the user group can not be
read.)
To set a parameter in the user group, set its parameter number in Pr. 173.
To delete a parameter from the user group, set its parameter number to Pr. 174. Set "9999" in Pr. 172 to batch delete
parameters registered.
Misoperation prevention and parameter setting restriction
Initial
Setting Range
Value
0
input from the operation panel or the forward/reverse rotation
Initial
Setting Range
Value
0
0
9999
0 to 999, 9999
9999
0 to 999, 9999
0
Both forward and reverse rotations allowed
1
Reverse rotation disabled
2
Forward rotation disabled
9999
Displays only the simple mode parameters
0
Displays simple mode + extended parameters
Displays the parameters registered in the user
1
group.
Displays the number of cases registered as a
(0 to 16)
user group (reading only)
9999
Batch clear the user group registration
Sets the parameter numbers to be registered to
the user group
Sets the parameter numbers to be cleared from
the user group
Description
Description
167