Reverse Rotation Prevention Selection (Pr. 78); Extended Parameter Display And User Group Function (Pr. 160, Pr. 172 To Pr. 174) - Mitsubishi Electric FR-E720-600 Instruction Manual

Hide thumbs Also See for FR-E720-600:
Table of Contents

Advertisement

Misoperation prevention and parameter setting restriction

4.18.3 Reverse rotation prevention selection (Pr. 78)

This function can prevent reverse rotation fault resulting from the incorrect input of the start signal.
Parameter
Number
Reverse rotation prevention
78
selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 180)
Set this parameter when you want to limit the motor rotation to only one direction.
This parameter is valid for all of the reverse rotation and forward rotation keys of the operation panel and parameter
unit(FR-PU04/FR-PU07), the start signals (STF, STR signals) via external terminals, and the forward and reverse rotation
commands through communication.

4.18.4 Extended parameter display and user group function (Pr. 160, Pr. 172 to Pr. 174)

Parameter which can be read from the operation panel and parameter unit can be restricted.
Parameter
Number
160
User group read selection
User group registered
172 ∗1
display/batch clear
173 ∗1, ∗2 User group registration
174 ∗1, ∗2 User group clear
∗1
The above parameters can be set when Pr. 160 User group read selection = "0".
∗2
The values read from Pr. 173 and Pr. 174 are always "9999".
(1) Display of simple mode parameters and extended parameters (Pr. 160)
When Pr. 160 = "9999", only the simple mode parameters can be displayed on the operation panel and parameter unit (FR-
PU04/FR-PU07). (Refer to the parameter list , page 54, for the simple mode parameters.)
In the initial setting (Pr. 160 = "0") status, simple mode parameters and extended parameters can be displayed.
REMARKS
When a plug-in option is fitted to the inverter, the option parameters can also be read.
When communication is used to read the parameters, all parameters can be read, regardless of the Pr. 160 setting.
When RS-485 communication is used to read the
parameters,
all
regardless of the Pr. 550 NET mode operation
command source selection, Pr. 551 PU mode operation
command source selection, regardless of Pr. 160
setting.
Pr. 15 JOG frequency, Pr. 16 JOG acceleration/deceleration time, and Pr. 991 PU contrast adjustment are displayed as simple mode
parameter when the parameter unit (FR-PU04/FR-PU07) is fitted.
180
Initial
Name
Value
Initial
Name
Value
0
0
9999
9999
parameters
can
be
read,
Setting Range
0
0
1
2
Setting Range
9999
0
1
(0 to 16)
9999
0 to 999, 9999
0 to 999, 9999
Pr. 551
2 (PU)
3 (USB)
9999
(auto detect initial
value)
* OP indicates a communication option.
Description
Both forward and reverse rotations allowed
Reverse rotation disabled
Forward rotation disabled
Description
Displays only the simple mode parameters
Displays simple mode + extended parameters
Displays the parameters registered in the user
group.
Displays the number of cases registered as a
user group (reading only)
Batch clear the user group registration
Sets the parameter numbers to be registered to
the user group
Sets the parameter numbers to be cleared from
the user group
Pr. 550
Pr. 160 Valid/Invalid
-
Valid
0 (OP)
Valid
Invalid (all parameters
2 (PU)
can be read)
With OP: valid
9999
Without OP: invalid
(auto detect initial
(all parameters can be
value)
read)

Advertisement

Table of Contents
loading

Table of Contents