A.6 Time History Software (Option 831C-LOG)
Time History Measurement System
Acoustic Measurements
Non-Acoustic Measurements
SoundAdvisor Model 831C
Time History can log an abundant selection of acoustic and non-acoustic metrics
at equal time intervals.
Time Period: Selectable for periods 2.5 ms, 5 ms, 10 ms, 20 ms, 50 ms, 100 ms, 200
ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 15 s, 20 s, 30 s, 1 min, 2 min, 5 min, 10 min, 15 min, 20
min, 30 min, 1 h, and 24 h
Synchronization: Selectable to sync to time-of-day clock, for periods of 1, 2, 5, 10,
15, 20, 30 seconds; 1, 2, 5, 10, 15, 20, 30 minutes; and 1, 24 hours
Metrics are individually selectable.
Period < 20 ms:
•
OBA 1/1 Leq*
•
OBA 1/3 Leq*
•
Period ≥ 20ms
•
L
, L
, L
, L
Aeq
Ceq
Zeq
APeak
Period ≥ 100 ms:
•
L
, L
, L
, L
Aeq
Ceq
Zeq
Apeak
•
L
, L
, L
, L
, L
AS
AF
AI
CS
CF
•
L
, L
, L
ASmax
AFmax
AImax
•
L
, L
, L
ASmin
AFmin
AImin
•
L
-L
, L
-L
Ceq
Aeq
AIeq
aeq,
*OBA processing must be installed (Firmware Option 831C-OB3), and the OBA
Bandwidth setting must be enabled on the meter.
Metrics are individually selectable.
Millisecond Resolution, Period < 1 s: Tms
Period ≥ 100 ms: Battery Voltage, External Power, Internal Temperature
426A12 or PRM2103 Metrics: Internal Temperature, Internal Humidity
SEN031 Metrics: Windspeed; Wind Gust Speed; Wind Direction; Temperature:
Avg, Min & Max; Humidity: Avg, Min & Max; Barometric Pressure
SEN032 Metrics: Windspeed; Wind Gust Speed; Wind Direction
, L
, L
Cpeak
Zpeak
, L
, L
Cpeak
Zpeak
, L
, L
, L
, L
CI
ZS
ZF
ZI
, L
, L
, L
CSmax
CFmax
CImax
, L
, L
, L
, L
CSmin
CFmin
CImin
L
AFTtm5
, L
, L
, L
ZSmax
ZFmax
ZImax
, L
, L
ZSmin
ZFmin
ZImin
A-33
Need help?