HP 98568A Installation Instruction page 158

Hp 9000 series 300 computers
Hide thumbs Also See for 98568A:
Table of Contents

Advertisement

HP 98628A Datacomm Interface
7. Set the Hardware Handshake.
a. Find the Default switch group by referring to Figure 5-24. Switches 4
and 5 in this group determine the hardware handshake.
b. Set the hardware handshake switches as follows:
• If connecting an HP 92205A/C Hayes SmartModem 1200, an HP
2334A X.25 Cluster Controller, or uucp, set switch 5 to 0 and set
switch 4 to
1.
This sets up a full duplex modem connection. The
switches will look like this:
Figure 5-28.
• If connecting an HP 2686 LaserJet printer, set both switches 5 and 4
to
1
as shown in Figure 5-24. This sets up a non-modem connection
with the handshake on.
• If connecting a terminal or HP 39800/01A bar code reader, set both
switches 4 and 5 to 0, which is opposite that shown in Figure 5-24.
This sets up a non-modem connection with the handshake off.
8. Set the Parity Type/Character Length.
a. Find the Default switch group by referring to Figure 5-24. Switches 6
and 7 in this group determine the parity type/character length.
b. Set the parity type/character length switches as follows:
• If connecting an HP 92205A/C Hayes SmartModem 1200, set the
parity type/character length switches to match the device you are
communicating with. Refer to the manual that came with the
interface for a list of settings.
• If connecting a terminal, an HP 2686 Laserjet printer, an HP 2601A
printer, or an HP 39800/01A bar code reader, set both switches 6 and
5-62
Adding Interface Cards

Hide quick links:

Advertisement

Table of Contents
loading