Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Retrieve
N/A
RCS?
Configuration
Status
Online Status
RED=
RED?
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
45 bytes
Query only.
Returns the configuration status of the unit.
EXAMPLES:
<0001/RCS?{CR}
ATT=12.75{CR}
AMP=1{CR}
MUT=1{CR}
ONL=1{CR}
ESW=1{CR}
AOF=00.00{CR}
AFR=1{CR}
XRF=NA{CR}{LF} (SEE NOTE)
Where:
ATT= attenuation in dB
AMP= RF power amplifier state where 0=OFF, 1=ON
MUT=RF mute state where 0=unmuted, 1=muted
RED=Online status for redundancy
ESW=Redundancy and mode states where 0=OFF, 1=ON Tx only, 2=ON Tx & Rx
AOF=Attenuator Offset in dB
AFR= auto fault recovery where 0=manual, 1=auto
XRF=External reference status where NA=no external reference, 05M=5 MHz,
and 10M=10 MHz
NOTE: XRF will always be NA if the internal reference oscillator option is not
installed.
1 byte
Command or Query.
Sets or returns Redundancy Online status in the form x, where:
0=Offline
1=Online
NOTE: This command is functionally identical to the ONL command.
COMMAND EXAMPLE: <0001/RED=1{CR}
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
5–31
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
RCS=
RCS=x....x
RED=
RED=x
RED?
RED*
MN-LPOD