Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Unit Alarm Mask MSK=
MSK?
Mute State
MUT=
MUT?
Number of
N/A
NUE?
Unread Stored
Events
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
5 bytes
Command or Query.
Sets or returns the alarm mask conditions in the form abcde where:
a=Low Forward RF Power
b=External Reference Lock detect
c=Fan Speed
d=LNB Current Detect
e=LNB 22V Power Supply
TYPICAL FOR EACH PARAMETER: 0=Fault, 1=Alarm, 2=Masked
NOTES:
1) Default value: 22111
2) If the value is set to 'Fault' (MSK=0) for a parameter, then the fault condition
will be logged as a fault if specified hardware conditions are not met.
3) If the mask value is set to 'Alarm' (MSK=1), then the fault condition will only
log as an alarm.
4) If the mask value is set to 'Masked' (MSK=2), then the fault condition will
not be reported to the user.
COMMAND EXAMPLE: <0001/MSK=22111{CR}
1 byte
Command or Query.
Sets or returns the unit muting in the form x, where:
0=Disable (Not Muted)
1=Enable (Muted) (DEFAULT)
2=Unit muted due to HW mute signal (SEE NOTE)
NOTE: This value is only shown in the response to a query, and cannot be issued
as a command. When MUT=2 this means that one of the "hardware" mute
conditions is present. Additionally, certain faults can generate a hardware mute,
e.g., BUC Lock Detect. If MUT=2, you must check the active faults and the status
of the auxiliary mute.
COMMAND EXAMPLE: <0001/MUT=1{CR}
3 bytes
Query only.
Unit returns the Number of Unread stored Events in the form xxx.
EXAMPLE: <0001/NUE?{CR}
>0001/NUE=126{CR}{LF}
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
5–27
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
MSK=
MSK=abcd
e
MSK?
MSK*
MUT=
MUT=x
MUT?
MUT*
NUE=
NUE=xxx
MN-LPOD