Comtech EF Data LPOD Series Installation And Operation Manual page 136

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Concise RF
N/A
CFS?
Power FET
Current Status
Circuit
CID=
CID?
Identification
Calibrate LNB
CLC=
CLC?
Current
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
Length varies
Query only.
depending on
Returns the power values of installed FETs, comma-delimited, in concise format.
the number of
NOTE: This is the condensed version of the RFS query.
installed FETs
EXAMPLE: <0001/CFS?{CR}
>0001/CFS=xxx,xxx,x.x,x.x,..........,x.x,{CR}{LF}
48 bytes
Command or Query.
Sets or returns the user-defined label for the unit or station.
NOTE: The 48-character string is entered as one line, but it is read back from the
unit as two 24-byte lines of information.
Default Setting: ------CID MESSAGE-------
------------------------
COMMAND EXAMPLE: <0001/CID= Station #001--SSPA #01--{CR}
QUERY EXAMPLE: <0001/CID?{CR}
>0001/CID={CR}
Station #001{CR}
--SSPA #01--{CR}{LF}
none
Command or Query.
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in
the form xxx.x.
Default value: 000.0
NOTES:
1) This command returns a mode error if the LNB current source output has
not been enabled first (see LCS command).
2) The LNB current alarm point is then determined by the calibrated LNB
reference point, and the LNB current window setting (see LCW command).
3) The CLC query returns the value that was stored during the LNB current
calibration.
COMMAND EXAMPLE: <1/CLC=xxx.x{CR} (where xxx.x is the calibrated LNB
current value in mA)
QUERY EXAMPLE: <1/CLC?{CR}
>0001/CLC=xxx.x{CR}{LF}
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
>0001/CID={CR}{LF}
5–16
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
CFS=
CFS=x;.....
x
CID=
CID=x;...x
CID?
CID*
CLC=
CLC=xxx.x
CLC?
CLC*
MN-LPOD

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpod ps 1Lpod ps 1.5Lpod ps 2

Table of Contents