Comtech EF Data LPOD Series Installation And Operation Manual page 156

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Serial Number*
N/A
RSN?
Retrieve Utility
N/A
RUS?
Status
Remote Baud
SBR=
SBR?
Rate
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
9 bytes
Query only.
Returns the unit's nine-digit serial number in the form xxxxxxxxx.
EXAMPLE: <0001/RSN?{CR}
>0001/RSN=0123445678{CR}{LF}
23 bytes,
Query only.
alphanumeric
Returns the utility status of the unit.
EXAMPLE: <0001/RUS?{CR}
>0001/RUS={CR}
ADR=0001{CR}
BDR=9600{CR}
REF=087{CR}{LF} (REF displays only if a reference oscillator is installed)
4 bytes
Command or Query.
Sets or returns the remote baud rate in the form xxxx, where:
2400=2400 baud
4800=4800 baud
9600=9600 baud (DEFAULT)
19K2=19200 baud
38K4=38400 baud
NOTE: When changing baud rates remotely the response to the command will be
returned using the same baud rate as that used to send the command.
COMMAND EXAMPLE: <0001/SBR=19K2{CR}
QUERY EXAMPLE: <0001/SBR?{CR}
>0001/SBR=9600{CR}{LF}
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
5–36
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
RSN=
RSN=xxxxx
xxxx
RUS=
RUS=x....x
SBR=
SBR=xxxx
SBR?
SBR*
MN-LPOD