Comtech EF Data LPOD Series Installation And Operation Manual page 149

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Online Status
ONL=
ONL?
Part Number
N/A
PNM?
Retrieve Alarm
N/A
RAS?
Status
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
1 byte
Command or Query.
Sets or returns the Redundancy Online status in the form x, where:
0=Offline (Query only) (SEE NOTE 2)
1=Online
NOTES:
1) The ONL query always returns an online response if the unit is not running in
redundancy mode. If redundancy is enabled then the query will indicate the
position of the Tx waveguide switch that enables one of the units to be
connected to the antenna.
2) Sending ONL=0 will not generate a syntax error; however setting ONL to zero
will not cause the unit to go offline. The online status is determined by the Tx
waveguide redundancy switch position, and only the offline unit may drive the
switches. Instead of sending ONL=0 to the online unit the ONL=1 command
should be sent to the offline unit to generate a redundancy switchover.
COMMAND EXAMPLE: <0001/ONL=1{CR}
96 bytes
Query only.
alphanumeric
Returns the Comtech EF Data part number of the unit. This part number is the
unit's DOTCODE at the time of manufacture. The DOTCODE may be up to 96
printable ASCII characters long.
EXAMPLE: <0001/PNM?{CR}
>0001/PNM=HPODC0.350WRSW00{CR}{LF}
168 bytes
Query only.
Returns the Alarm status of the unit, where:
OK=No fault condition; FT=Faulted; AL=Alarm; YS=Yes; NO=No; MS=Masked.
EXAMPLE:
<0001/RAS?{CR}
>0001/RAS={CR}
P24V1=OK{CR} (+24V power supply)
P24V2=NA{CR} (+24V switch power supply)
LNBVT=XXXXX{CR} (+13/18V LNB power supply) (SEE NOTE)
P13VT=OK{CR} (+13.5V power supply)
P10V1=OK{CR} (+10V power supply)
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
5–29
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
ONL=
ONL=x
ONL?
ONL*
PNM=
PNM=x....x
PNM?
PNM *
RAS=
RAS=x....x
MN-LPOD