Comtech EF Data LPOD Series Installation And Operation Manual page 148

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Number of
N/A
NUS?
Unread Stored
Statistics
Offline Mute
OFM=
OFM?
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
3 bytes
Query only.
Unit returns the Number of Unread stored Statistics in the form xxx.
EXAMPLE: <0001/NUS?{CR}
>0001/NUS=126{CR}{LF}
1 byte
Command or Query.
Sets or returns offline mute in the form x, where:
0=Disable (Not Muted)
1=Enable (Muted)
2=Mute RX
3=Mute Tx
4=Mute Rx+LNB
5= Mute Tx+LNB
6=Mute Tx+AMP
7=Mute Tx+LNB+AMP
NOTE: LNB Voltage of Online unit shows on Status page of Offline unit when
Offline Mute is set to 4 or 5. This is caused by voltage feedback from Online unit
to Offline unit via RF splitter.
EXAMPLE: <1/OFM=1{CR}
>0001/OFM={CR}}{IF}
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
5–28
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
NUS=
NUS=xxx
OFM=
OFM=x
OFM?
MN-LPOD

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpod ps 1Lpod ps 1.5Lpod ps 2

Table of Contents