Graphs
Click [Refresh] to see the latest graph data.
This scrolling page provides graphs that show trends over time for the following operating
parameters:
•
Amplifier Temperature
•
Amplifier Output Power
•
LNB Current
•
Operating Status
•
Rx Mute Status
•
Online Status
•
Minimum Fan Speed
Trending Graph Time Settings
Choose the time, date, and duration of the trending information displayed on the graphs.
•
Start Date (mm/dd/yy): Once a unit has been in operation for 24 hours or more, use the
drop-down list to select a date – up to a maximum of 28 days, including the present date
– from which to compile data. If a unit has not been in operation for 24 hours, only
present will be available.
•
Time: Once a unit has been in operation for 24 hours or more, use this drop-down list to
select the time on the hour – 24 hours, from 12 am to 11 pm, are available. Note that, for
the first 24 hours of operation (or beyond if the time has accrued), if you select present
as the Start Date, then the Time drop-down list becomes unavailable for selection and
dims as shown here.
•
Duration: Use the drop-down list to select the block of time in which data is compiled for
the graphs. Select 30 minutes, 1 hour, 2 hours, 4 hours, 6 hours, 8 hours, 12 hours,
24 hours, or 48 hours.
The LPOD stores the trending data to flash memory once per hour. If you
power down the unit before the data can be written to memory, the last 60
minutes of data will be lost.
Click [Submit] to execute your settings choices.