Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Maximum
N/A
MOP?
Operating Point
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
272 bytes
Query only.
Returns the maximum operating point of the unit along with its timestamp in the
reply format:
MAXFET=sYYYC mmddyy hhmmss{CR}
MINFET=sYYYC mmddyy hhmmss{CR}
MAXPFT=sYYYC mmddyy hhmmss{CR}
MAXDTP=sYYYC mmddyy hhmmss{CR}
MAXHTS=sYYYC mmddyy hhmmss{CR}
MINHTS=sYYYC mmddyy hhmmss{CR}
MAXOST=sYYYC mmddyy hhmmss{CR}
MAXRFP=sZZ.ZZ mmddyy hhmmss{CR}
MINRFP=sZZ.ZZ mmddyy hhmmss{CR}
Where:
sYYYC is the temperature
sZZ.ZZ is the power
NOTE: Not all LPODs have outside temperature monitor. In which case MAXOST
and MINOST report XXXXX XXXXXX XXXXXX
EXAMPLE: <0001/MOP?{CR}
>0001/mop={CR}
MAXFET=+000C 010208 180729{CR}
MINFET=+000C 010208 180729{CR}
MAXPFT=+000C 010208 180659{CR}
MAXDTP=+000C 010208 180729{CR}
MAXHTS=+050C 010208 180729{CR}
MINHTS=+050C 010208 180729{CR}
MAXOST=XXXXX XXXXXX XXXXXX{CR}
MINOST=XXXXX XXXXXX XXXXXX{CR}
MAXRFP=+00.00 010208 180659{CR}
MINRFP=+00.00 010208 180659{CR}
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
5–26
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
MOP=
MN-LPOD