Comtech EF Data LPOD Series Installation And Operation Manual page 137

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

Controller-to-Target
Parameter
Instruction Code and
Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Concise
N/A
CMS?
Maintenance
Status
Serial Interface Operation
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
95 bytes
Query only.
Returns the Maintenance status of the unit, response is semicolon-delimited, in
the form
aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;
ooo.o;ppp.p;qqq.q;rrr.r;sss.s;ttt.t where:
aaa.a=P24V1
bbb.b=P24V2
ccc.c=LNBVT (SEE NOTE 2)
ddd.d=P13VT
eee.e=P10V1
fff.f=A10V1
ggg.g=A10V2 (SEE NOTE 2)
hhh.h=P7V8T
iii.i=P5V8T
jjj.j=P2V5T
kkk.k=P1V2T
lll.l=N5V8T
mmm.m=FANR1 (SEE NOTE 2)
nnn.n=FANR2 (SEE NOTE 2)
ooo.o=BUCVT (SEE NOTE 2)
ppp.p=FWPWR
qqq.q=REFVT (SEE NOTE 2)
rrr.r=LNBCS (SEE NOTE 2)
sss.s=ATEMP
ttt.t=OTEMP (SEE NOTE 2)
NOTES:
1) This is the concise version of the RMS command.
2) ccc.c, ggg.g, mmm.m, nnn.n, ooo.o, qqq.q, rrr.r, and ttt.t will appear if the
appropriate model/options have been selected/installed. Otherwise, the
unused fields will display XXXXX.
EXAMPLE: <1/CMS?{CR}
>0001/CMS=aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m
;nnn.n;ooo.o;ppp.p;qqq.q; rrr.r;sss.s;ttt.t{CR}{LF}
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Description of Arguments
5–17
Revision 15
Target-to-Controller
(see Description of
Arguments)
Response to
Response
Command
to Query
CMS=
CMS=x....x
MN-LPOD

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpod ps 1Lpod ps 1.5Lpod ps 2

Table of Contents