Application Functions - Danfoss VLT HVAC Drive FC 100 Instruction Manual

Hvac low harmonic drive
Hide thumbs Also See for VLT HVAC Drive FC 100:
Table of Contents

Advertisement

6 How to Program the Low Harmonic Drive

6.3.20 22-** Application Functions

Par.
Parameter description
No. #
22-0* Miscellaneous
22-00
External Interlock Delay
22-01
Power Filter Time
22-2* No-Flow Detection
22-20
Low Power Auto Set-up
22-21
Low Power Detection
22-22
Low Speed Detection
22-23
No-Flow Function
22-24
No-Flow Delay
22-26
Dry Pump Function
22-27
Dry Pump Delay
22-3* No-Flow Power Tuning
22-30
No-Flow Power
22-31
Power Correction Factor
22-32
Low Speed [RPM]
22-33
Low Speed [Hz]
22-34
Low Speed Power [kW]
22-35
Low Speed Power [HP]
22-36
High Speed [RPM]
6
22-37
High Speed [Hz]
22-38
High Speed Power [kW]
22-39
High Speed Power [HP]
22-4* Sleep Mode
22-40
Minimum Run Time
22-41
Minimum Sleep Time
22-42
Wake-up Speed [RPM]
22-43
Wake-up Speed [Hz]
22-44
Wake-up Ref./FB Difference
22-45
Setpoint Boost
22-46
Maximum Boost Time
22-5* End of Curve
22-50
End of Curve Function
22-51
End of Curve Delay
22-6* Broken Belt Detection
22-60
Broken Belt Function
22-61
Broken Belt Torque
22-62
Broken Belt Delay
22-7* Short Cycle Protection
22-75
Short Cycle Protection
22-76
Interval between Starts
22-77
Minimum Run Time
22-78
Minimum Run Time Override
22-79
Minimum Run Time Override Value
22-8* Flow Compensation
22-80
Flow Compensation
22-81
Square-linear Curve Approximation
22-82
Work Point Calculation
22-83
Speed at No-Flow [RPM]
22-84
Speed at No-Flow [Hz]
22-85
Speed at Design Point [RPM]
22-86
Speed at Design Point [Hz]
22-87
Pressure at No-Flow Speed
22-88
Pressure at Rated Speed
22-89
Flow at Design Point
22-90
Flow at Rated Speed
6-58
Default value
(SR = Size related)
0 s
0.50 s
[0] OFF
[0] Disabled
[0] Disabled
[0] OFF
10 s
[0] OFF
10 s
0.00 kW
100 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
10 s
10 s
ExpressionLimit
ExpressionLimit
10 %
0 %
60 s
[0] OFF
10 s
[0] OFF
10 %
10 s
[0] Disabled
start_to_start_min_on_time
(P2277)
0 s
[0] Disabled
0.000 ProcessCtrlUnit
[0] Disabled
100 %
[0] Disabled
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
0.000 N/A
999999.999 N/A
0.000 N/A
0.000 N/A
®
MG.16.A1.22 - VLT
is a registered Danfoss trademark
VLT HVAC Low Harmonic Drive Instruction
4 set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
0
2 set-ups
TRUE
-2
All set-ups
FALSE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
1
All set-ups
TRUE
0
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
1
All set-ups
TRUE
-2
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
1
All set-ups
TRUE
-2
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
FALSE
-
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
Manual
Type
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint16
Uint32
Uint16
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Uint16
Uint16
Int8
Int8
Uint16
Uint8
Uint16
Uint8
Uint8
Uint16
Uint8
Uint16
Uint16
Uint8
Int32
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Int32
Int32
Int32
Int32