Fix the Media Thickness Checking Sensor Unit by using the
10
Block
[1000008363 : TOOL,BLOCK LEJ-640 ST-122]
following the below steps.
Block
Projection
Set the projection part of the block into the groove.
<Above view>
Adjust the position of the Unit by pushing downward
the blue colored area of the Unit as shown in the fi gure.
Remove the block by sliding it to the left.
11
Turn on the sub power while pressing the Left, Right
12
and Down keys to enter the Service Mode.
Media Thickness Checking Sensor Unit
by
Block
While holding the Sensor Unit up, slide the Block to put it
under the unit.
<Side view>
Fix the 2 screws in order as shown in the
fi gure while holding the adjusted position.
Block
4-78
1
2
+
MENU
MENU
SERVICE MENU