Perform the following operations if it is not possible to transfer the parameters by Peck.exe.
1. BATTERY INSTALLATION
Fix the battery in reference to step 3 and 4 in [3-9 BATTERY REPLACEMENT].
2. FIRMWARE INSTALLATION
Refer to [4-2 HOW TO UPGRADE/INSTALL FIRMWARE]
3. SYSTEM PARAMETER INITIALIZE
Refer to [4-2 HOW TO UPGRADE/INSTALL FIRMWARE]
4. TIME AND DATE SETTING
Set the date and time in [SERVICE MENU] > [SUB MENU] > [CLOCK].
*Set [DATE] in order of [Year/Month/Day].
5. IP ADDRESS SETTING
Start the machine with the Service Mode and set in the User Menu.
6. FIRMWARE VERSION CONFIRMATION OF NETWORK CONTROLLER
Refer to [4-3 HOW TO UPGRADE FIRMWARE OF THE NETWORK CONTROLLER]
7. HEAD RANK SETTING
It can be set in [PRINT MENU] > [HEAD RANK].
8. SERIAL NUMBER INPUT
It can be set in [SUB MENU] > [SERIAL NO.].
9. INK TYPE SETTING
It can be set in [SUB MENU] > [CHANGE INKTYPE].
10. CAP & WIPER CHECK
It can be performed in [SERVICE MENU] > [I/S MENU] > [I/S CHECK].
11. CAP HEIGHT CHECK
It can be performed in [SERVICE MENU] > [I/S MENU] > [CAP ADJUST] > [CHECK GAP].
12. SENSOR CHECK
It can be performed in the Sensor Check.
13. LIMIT POSITION& CUT DOWN POSITION INITIALIZE
Refer to [4-5 LIMIT POSITION & CUT DOWN POSITION INITIALIZE]
14. LINEAR ENCODER SETUP
Refer to [4-6 LINEAR ENCODER SETUP]
15. PAPER SIDE SENSOR ADJUSTMENT
Refer to [4-14 PAPER SIDE SENSOR ADJUSTMENT].
16. HEAD ALIGNMENT
Refer to [4-4 HEAD ALIGNMENT]
Only Horizontal and Bidirectional Adjustment are required.
17. CALIBRATION
Refer to [4-8 CALIBRATION]