Roland VersaUV LEJ-640 Service Notes page 217

Uv led printer
Hide thumbs Also See for VersaUV LEJ-640:
Table of Contents

Advertisement

MOTOR MENU
SERVO LOCK
SERVICE MENU
SYSTEM SWITCH
SYSTEM SWITCH
PAGE1
SYSTEM SWITCH
PAGE16
HISTORY MENU
SERVICE MENU
HISTORY MENU
MOTOR GROUP
In History Menu, the parameters are separated in groups
by categories. The parameters can be displayed or cleared
by entering the menu of each groups.
SERVICE MENU
REPORT
REPORT
SERVICE REPORT
REPORT
HISTORY REPORT
REPORT
CARTRIDGE
REPORT
EVENT LOG
REPORT
SERIAL
UV LAMP MENU
SERVICE MENU
UV LAMP MENU
SVC.MODE LAMP
UV LAMP MENU
CONNECT CHECK
UV LAMP MENU
LAMP ON CHECK
UV LAMP MENU
LAMP ON AGING
UV LAMP MENU
SLIDE
Servo Motor : LOCKED
SERVO LOCK
SERVO LOCK
F:
S:
100
Servo Motor : FREE
SERVO LOCK
SERVO LOCK
F:
240
20
F:
PAGE1
00000000
bit #[ 8 7 6 5 4 3 2 1 ]
Revised 11
PAGE16
00000000
* All the default settigs that are not shown here is "0".
bit #[ 8 7 6 5 4 3 2 1 ]
CAUTION : The machine may make unexpected move when the other system switches that are not
shown here are changed.
MOTOR HOURS F
MOTOR HOURS F
3 hours
CLEAR
CATEGORIES : MOTOR GROUP / HEAD GROUP /
MAINTE GROUP / WIPE GROUP /
PRINT GROUP / INK GROUP /
 
ERROR GROUP / SYSTEM GROUP/
UVLAMP GROUP /
SERVICE REPORT
Reports can be printed. Each head is separately selectable considering the case of head trouble.
HEAD H1
Select a head with [up] and [down] key and press [ENTER] key to start printing.
H1/H2/H3/H4/H5/H6
SERVICE : Service Report is printed. It prints the System Report of the normal menu with additional
Service Information.
HISTORY REPORT
HISTORY : History Report is printed.
HEAD H1
CARTRIDGE : Ink Cartridge IC Report is printed.
EVENT LOG : Event Log Report is printed. The number of Event to be printed is selectable from
H1/H2/H3/H4/H5/H6
100/200/ALL(400).
ALL : All Reports are printed together. (System Report, Service Report, History Report, Ink Cartridge
CARTRIDGE
HEAD H1
SERIAL : Service Report and History Report can be sent to RS-232C Serial using special tool.
H1/H2/H3/H4/H5/H6
SELECT MAXIMUM
EVENT LOG
100 LOGS
HEAD H1
Setting Value : 100LOGS/200LOGS/ALL
SVC.MODE LAMP
ON
OFF
UV Lamp : Not connected
CONNECT CHECK
NOT CONNECTED
UV Lamp : connected
CONNECT CHECK
CONNECTED
Left UV Lamp : ON
RIGHT:
NOW PROCESSING...
LEFT : * :[ ]
Right UV Lamp : error
RIGHT: _ :[E]
This menu is to check the power, lighting/
LEFT :
error and connection of the UV Lamps.
* Perform with the covers closed except for
the power check. Refer to [4-13 UV LAMP
CHECK].
LAMP ON AGING
NOW AGING
SLIDE
NOW PROCESSING..
SLIDE CHECK
SLIDE
NOW PROCESSING..
SLIDE AGING
SLIDE
SLIDE CONTROL
SLIDE CONTROL
HOME
SLIDE CONTROL
FRONT
4-9
This menu is to check whether Servo Motor can be locked properly.
While in this menu, Servo Motor is free. When the Carriages are
0
0
moved by hands, the displayed values change as the feedback is
performed normally. Servo Motor can be locked by pressing
[ENTER] key. When it is locked while the motor is in pause,
the normal power control is performed. As for [F(Feed direction)],
the value displayed on the left changes by Grid Encoder,
0
0
and the right changes by Motor Encoder.
This menu is to change the functions of the machine. Normally, it is not necessary to change.
Each bit can be selected by [left] and [right] keys and changed by [up] and [down] keys.
Press [ENTER] to save the settings. There are 16 pages for every 8 bits System Switch.
Bit
Contents
With [1], the error does not occur even if the
PAGE1:Bit1
Cover Sensor
Front Cover is open.
Reflection to the test pattern
[1] enables the settings of [FULL WIDTH S]
PAGE1:Bit4
of the Full Width
for all test patterns.
Periodic flushing that
Enables with [0], Disables with [1].
PAGE1:Bit7
takes place every 8 hours
With [1], [STANDARD HEAD] menu is added to
PAGE2:Bit6
Standard Head Menu
the Service Menu.
0 : Current UV lamp position
PAGE7:Bit7
UV lamp position
1 : New UV lamp position
The menu shown on the upper LCD can be changed with [up] and [down] keys.
The corresponding parameter is shown on the lower LCD. Refer to the HISTORY MENU
List on the following pages. Press [right] key to enter [CLEAR] menu, and parameter
can be cleard by pressing [ENTER] key.
IC Report, Event Log Report).
(9600bps, N81, X : ON/OFF)
Required Printing Area
SERVICE : W350 L410mm
HISTORY : W250 L210mm
CARTRIDGE : W250 L85mm
EVENT LOG/100 LOGS : W350 L200mm
EVENT LOG/200 LOGS : W350 L330mm
EVENT LOG/ALL LOGS : W350 L590mm
This is to set ON/OFF of the UV Lamp during the printing when the machine is started in the
Service Mode. This setting is initialized when turning off the sub power SW. Default : ON
This is to check whether the UV Lamp is connected properly.
:[ ]
NOW PROCESSING...
Select the right or left Lamp by moving the cursor with [up]
and [down] keys. And check that the selected Lamp can be
:[ ]
operated properly by turning ON/OFF the Lamp by pressing
[ENTER] key.
Error displays : E
Check that the UV Lamps can be operated properly by opening
and closing the cover while the UV Lamps are turned on.
This menu is to perform the aging for the direction of SCAN with the right and left UV lamps
lighted. This menu can be performed with the machine that is not filled ink. Before performing
this menu, set to [ON] in [SVC. MODE LAMP] menu.
Normal
SLIDE CHECK
COMPLETED
Error
SLIDE CHECK
FAILED !!
Normal
SLIDE AGING
COMPLETED
Error
SLIDE AGING
FAILED !!
This menu is for checking the movement of the slide motor.
Selection : HOME/FRONT
Default : HOME
Settings
Default
0
0
0
0
0
This menu is for checking
the slide motor and slide
limit sensor.
This menu is to check
that the slide motor moves
within the range of
movement properly.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents