Connect the UV Lamp Cable, Motor Cable and Sensor Cable
12
to the Carriage Board.
Slide the UV Lamp to the front
and bundle the cables with the Wire Saddles.
Turn on the Sub Power while pressing the Left, Right and
13
Down keys to enter the Service mode.
Select [I/S MENU] > [I/S CONTROL] > [HEAD UP/DOWN]
14
> [MIDDLE], and press the [ENTER] key. The Capping Unit
moves down and the Head Carriage moves to the Middle po-
sition.
Turn off the Sub Power SW and Main Power SW.
15
MENU
SERVICE MENU
SERVICE MENU
I/S MENU
I/S MENU
I/S CONTROL
I/S CONTROL
HEAD UP/DOWN
HEAD UP/DOWN
MIDDLE
Sub Power SW
3-106
Motor Cable
Sensor Cable
UV Lamp Cable
Carriage Board
+
MENU
[
]
[
]
[
]
[
]
< Rear side >
Main Power SW