Roland VersaUV LEJ-640 Service Notes page 223

Uv led printer
Hide thumbs Also See for VersaUV LEJ-640:
Table of Contents

Advertisement

Other Factory Mode
SYSTEM PARAMETER INITIALIZATION
ENTER
INITIALIZE ALL
SYS.PARAMETER
SELECT MODEL
LEJ-640
INITIALIZATION
COMPLETED
DISPLAYED LANGUAGE
+
MENU
Roland DG Corp.
LEC-540
MENU LANGUAGE
ENGLISH
[ ]
LENGTH UNIT
mm
>
INCH
[ ]
TEMP. UNIT
C
>
F
All parameters will be initialized. Turn on the sub power SW
+
while pressing the Up, Down and [ENTER] keys to start the
machine in SYSTEM PARAMETER INITIALIZE mode.
Press the [ENTER] key to initialize the SYSTEM
PARAMETER or press the [POWER] key to cancel when
the confi rmation message is displayed. The machine turns
off automatically when the initialization is completed. All the
[ ]
parameters are reset to the default.
It is necessary to setup the LIMIT POSITION after the
initialization. The error message [SERVICE CALL 0101] is
[ ]
displayed and the machine will not start before the LIMIT
POSITION is set up.
SERVICE REPORT PRINTING
SERVICE REPORT
Turn on the sub power SW while
+
pressing the Down key to start the
machine in the SERVICE REPORT
PRINTING mode.
[SERVICE REPORT] is displayed
and it returns to the normal mode
after printing.
It starts printing automatically when
media is setup. It requires a A4 size
media and prints with Cyan ink.
* Please print [HISTORY REPORT]
from the Service Mode.
4-15