Connect the connector of the Pump Motor.
13
Move the Head Carriage to the capping position by hand.
14
After turning on the Main power SW, turn on the Sub Power
15
SW while pressing the Left, Right and Down keys to enter
the Service Mode.
Select [I/S MENU] > [I/S CONTROL] > [CAP] > [CLOSE],
16
and press the [ENTER] key to move the Capping Unit up 1
step. Align the Guides at the two ends of the Capping Unit
with the Guides at the two ends of the Head Carriage by
moving the Head Carriage by hand. Then press the [ENTER]
key twice more to Cap the Heads with adjusting the position
of the Head Carriage.
Connector
MENU
SERVICE MENU
Guide
3-38
+
MENU
Guide