5.4.3
Overview of states, fan/battery module
The states that can occur during operation are described in the following.
Table 5-9
Overview of states
State
Fan
4)
Failure of one
Single fan
fan during
STOP, then
RUN
Double fan
Failure of
Double fan
both fans dur‐
ing STOP,
then RUN
Failure of one
Single fan
fan during
RUN
Double fan
Failure of
Double fan
both fans dur‐
ing RUN
SIMOTION D4x5-2 switches to the RESET state after approximately 1 minute.
1)
Maintenance: Replace double fan/battery module at the next available opportunity.
2)
The "YES" value must be reset to "NO" by the application.
3)
Single fans are only supported by SIMOTION D4x5 and D410-2.
4)
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
PeripheralFaultTask
Diagnostic buffer entry
PeripheralFaultTask:
Is not called
Diagnostic buffer entry:
Fan on the module is defective
PeripheralFaultTask:
Is not called
Diagnostic buffer entry:
There is no redundant fan available
PeripheralFaultTask:
Is not called
Diagnostic buffer entry:
Fan on the module is defective
PeripheralFaultTask:
TSI#InterruptId =
_SC_PC_INTERNAL_FAILURE (= 205)
TSI#details = 16#00000080
Diagnostic buffer entry:
Fan on the module is defective
PeripheralFaultTask:
TSI#InterruptId =
_SC_PC_INTERNAL_FAILURE (= 205)
TSI#details = 16#00004000
Diagnostic buffer entry:
There is no redundant fan available
PeripheralFaultTask:
TSI#InterruptId =
_SC_PC_INTERNAL_FAILURE (= 205)
TSI#details = 16#00000080
Diagnostic buffer entry:
Fan on the module is defective
Commissioning (hardware)
System variables
3)
_cpuDataRW.
_cpuDataRW. redun‐
fanWarning
dantfanWarning
= YES
= NO
= NO
= YES
= YES
= NO
1)
= YES
= NO
= NO
= YES
= YES
= NO
1)
5.4 Fan