Commissioning (hardware)
4.4 Fan
4.4.3

Overview of states, fan/battery module

The states that can occur during operation are described in the following.
Table 4- 9
Overview of states
State
Fan
Failure of one fan
Single fan
during STOP,
then RUN
Double fan
Failure of both
Double fan
fans during
STOP, then RUN
Failure of one fan
Single fan
during RUN
Double fan
Failure of both
Double fan
fans during RUN
SIMOTION D4x5-2 switches to the RESET state after approximately 1 minute.
1)
Maintenance: Replace double fan/battery module at the next available opportunity.
2)
The "YES" value must be reset to "NO" by the application.
3)
Single fans are only supported by SIMOTION D4x5 and D410-2.
4)
108
PeripheralFaultTask
4)
Diagnostics buffer entry
PeripheralFaultTask:
Is not called
Diagnostics buffer entry:
Fan on the module is defective
PeripheralFaultTask:
Is not called
Diagnostics buffer entry:
There is no redundant fan available
PeripheralFaultTask:
Is not called
Diagnostics buffer entry:
Fan on the module is defective
PeripheralFaultTask:
TSI#InterruptId =
_SC_PC_INTERNAL_FAILURE (= 205)
TSI#details = 16#00000080
Diagnostics buffer entry:
Fan on the module is defective
PeripheralFaultTask:
TSI#InterruptId =
_SC_PC_INTERNAL_FAILURE (= 205)
TSI#details = 16#00004000
Diagnostics buffer entry:
There is no redundant fan available
PeripheralFaultTask:
TSI#InterruptId =
_SC_PC_INTERNAL_FAILURE (= 205)
TSI#details = 16#00000080
Diagnostics buffer entry:
Fan on the module is defective
System variables
_cpuDataRW.
fanWarning
= YES
= NO
= YES
1)
= YES
= NO
= YES
1)
Commissioning and Hardware Installation Manual, 02/2012
3)
_cpuDataRW.
redundantfanWarning
2)
= NO
= YES
= NO
= NO
= YES
= NO
SIMOTION D4x5-2