Configuration of the on‐
board I/Os
CF card / firmware
Mixture of Control Units of
different generations
Connectable drive compo‐
nents
User program
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Explanation
The configuration of the onboard I/Os is retained. Functionality, quantity structure and terminal
designations of the onboard I/Os for the D4x5-2/CX32-2 differ from the previous modules
because of innovations. Example:
● D4x5‑2 has additional technology I/Os on terminal block X142 (e.g. for high-precision cam
outputs); a cam output on X122/X132 is no longer supported
● Terminal blocks X122/X132 have additional digital inputs and therefore the pin
assignments on the terminal block have been moved.
SIMOTION D4x5 and D4x5‑2 have different CompactFlash cards and different card mappers
(firmware).
1 GB CF cards of the D4x5 can also be used for the D4x5‑2 when a new boot loader is loaded.
For details, see Section Boot loader on the CompactFlash card (Page 374).
The firmware version of a Controller Extension (CX) is always identical to the SINAMICS
Integrated. Therefore
● The CX32 can only be operated on the D4x5
● The CX32‑2 can only be operated on the D4x5‑2
These dependencies do not apply for SINAMICS S120 Control Units.
A CU320 can therefore be operated on a D4x5‑2.
As for the CU320‑2, some older drive components are also no longer supported by the D4x5‑2/
CX32‑2.
For details, see Section Permissible combinations (Page 334)
In principle, a D4x5 user program can run on a D4x5‑2, however, adaptations may be required
because of innovations in the hardware. Examples:
● The non-volatile data is backed up permanently and maintenance-free for the D4x5‑2
(backed-up SRAM for D4x5); a buffer failure signaled via
persistentDataPowerMonitoring.powerFailure = "YES" therefore only applies to the real-
time clock, not for the non-volatile data.
● The runtime behavior of the D4x5‑2 modules changes because of the increase in
performance. As long as the user program does not contain any "runtime-dependent code",
adaptations should not be necessary.
● The D4x5‑2 has a double fan module. The user program must be adapted in order to profit
from the advantages of a double fan compared with a single fan (identification of required
maintenance). See Section Overview of the fan/battery module states (Page 119).
● The user program will have to be modified with respect to detection of the maintenance
case for D425‑2/D435‑2 if D425/D435 was used without a fan/battery module. See Section
Overview of states, fan/battery module (Page 119).
● The batterynecessary and fannecessary system variables have different states depending
on the device. See
Section Operations and their effect on the user memory (Page 106) and
Section Cooling the SIMOTION D4x5-2 (Page 117)
● As of SIMOTION V4.3, the following additional functions are available for the D4x5‑2:
System variables rtcFailure and retainDataFailure
Backup of the non-volatile SINAMICS data (NVRAM data) via CU parameter p7775
Automatic detection of a module replacement on the basis of the serial number of the
Control Unit
7.22 Migration of SIMOTION D4x5 to SIMOTION D4x5-2
Commissioning (software)
333