Assignment Of The Profibus Addresses In Hw Config - Siemens SIMOTION D4x5-2 Commissioning And Hardware Installation Manual

Hide thumbs Also See for SIMOTION D4x5-2:
Table of Contents

Advertisement

Parameter assignment / addressing
6.3 Configuring PROFIBUS DP
X126
X136
DP
DP/MPI
DP master, iso‐
DP master, not
chronous
isochronous
DP master, iso‐
DP slave, not
chronous
isochronous
DP master, not
DP master, iso‐
isochronous
chronous
DP slave, not
DP master, iso‐
isochronous
chronous
DP master, not
DP master, not
isochronous
isochronous
DP slave, not
DP master, not
isochronous
isochronous
DP master, not
DP slave, not
isochronous
isochronous
DP slave, not
DP slave, not
isochronous
isochronous
DP slave, iso‐
DP slave, not
chronous
isochronous
DP slave, not
DP slave, iso‐
isochronous
chronous
For detailed information about controlling synchronization across the application, see the
Functions for Modular Machines Description of Functions.
Alternatively, the X136 interface can be used as an MPI interface with a transmission rate of
19.2 kbit/s up to 12 Mbit/s.
6.3.3

Assignment of the PROFIBUS addresses in HW Config

Assigning PROFIBUS addresses
In order for all devices to communicate with each other, you must assign a PROFIBUS address
to each device before connecting them:
Note
Before you assign any PROFIBUS addresses, please remember that all addresses must be
unique on the PROFIBUS subnet.
134
Remark
Application synchronized to DP master (X126)
Internal drive is synchronous with X126
Cycle clock X126 = cycle clock DP Integrated
Application synchronized to DP master (X126)
Internal drive is synchronous with X126
Cycle clock X126 = cycle clock DP Integrated
Application synchronized to DP master (X136)
Internal drive is synchronous with X136
Cycle clock X136 = cycle clock DP Integrated
Application synchronized to DP master (X136)
Internal drive is synchronous with X136
Cycle clock X136 = cycle clock DP Integrated
Application synchronized to internal drive cycle clock
Application synchronized to internal drive cycle clock
Application synchronized to internal drive cycle clock
Application synchronized to internal drive cycle clock
Application synchronized to DP slave (X126) (can be moni‐
tored by the application)
Internal drive is synchronous with X126
Application synchronized to DP slave (X136)
(can be monitored by the application)
Internal drive is synchronous with X136
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Actions in the application
None
None
None
None
None
None
None
None
DP slave synchroniza‐
tion mechanisms
DP slave synchroniza‐
tion mechanisms
Basic
SIMOTION D4x5-2